Article View: sci.electronics.design
Article #90Re: nasa-celebrates-successful-mars-landing
From: josephkk
Date: Fri, 10 Aug 2012 02:52
Date: Fri, 10 Aug 2012 02:52
232 lines
11355 bytes
11355 bytes
On Tue, 07 Aug 2012 20:36:55 -0700, Jon Kirwan <jonk@infinitefactors.org> wrote: >On Tue, 07 Aug 2012 19:34:24 -0700, josephkk ><joseph_barrett@sbcglobal.net> wrote: > >>On Tue, 07 Aug 2012 14:04:19 -0700, Jon Kirwan <jonk@infinitefactors.org> >>wrote: >> >>>On Tue, 7 Aug 2012 12:42:56 -0700 (PDT), George Herold >>><gherold@teachspin.com> wrote: >>> >>>>On Aug 7, 3:19 pm, Jon Kirwan <j...@infinitefactors.org> wrote: >>>>> On Tue, 7 Aug 2012 05:23:52 -0700 (PDT), dp <d...@tgi-sci.com> >>>>> wrote: >>>>> >>>>> >>>>> >>>>> >>>>> >>>>> >On Aug 7, 5:11 am, Jon Kirwan <j...@infinitefactors.org> wrote: >>>>> >> ...(Most of my work was in the >>>>> >> visible, near UV, and near IR -- but for very different >>>>> >> applications.) I still have some decent setups here and I've >>>>> >> designed some devices that can be made for only a few >>>>> >> dollars, and wavelength calibrated for $8 more, so that high >>>>> >> school students could actually built their own real-world >>>>> >> equipment that could genuinely "do science" and meet >>>>> >> calibration standards. No intensity calibration, though, >>>>> >> sadly. That costs money to do. (Unless you have a suggestion >>>>> >> about how to do it on the cheap?) >>>>> >>>>> >Oh no, I could not possibly have a suggestion. My spectrometers >>>>> >don't seem to have an overlapping wavelength range with yours, >>>>> >mine are xray/gamma. I am practically clueless when it comes to >>>>> >those in the UV and below range, mine generally count single >>>>> >photons. >>>>> >>>>> For all those reasons, that is why I would LOVE to see the >>>>> "optics" (and the schematics, as well.) Totally new area for >>>>> me to learn about. In my region, it's all about electron >>>>> transitions -- and no molecular dissassociation. >>>>> >>>>> I'd expect you'd count single photons at those energies -- >>>>> just one probably creates quite a shower to deal with. I'd >>>>> like to know, in practice, how one measures the energy. >>>>> >>>>> Also, in space there is a serious problem with "brown crud", >>>>> which is smashed, charged particles that come from the >>>>> satellite's own fabrication scattered into space, which >>>>> because it is charged comes back to the spacecraft at some >>>>> later time, but sticks elsewhere (not where you want it.) I >>>>> don't know if there is a problem with this on Mars -- there >>>>> is an atmosphere of sorts. But I'm curious just the same if >>>>> there is an accumulation problem and how it is dealt with. >>>>> >>>>> >Efficiency calibration is costly on those for gamma, too, >>>>> >though - the calibration source costs thousands. The rest, hm, >>>>> >has become much less expensive since the release of the >>>>> >netmca-3 (one can still spend tens of thousands on it but >>>>> >does not have to any longer). >>>>> >>>>> Now THAT I totally believe. I probably couldn't afford it. >>>>> But I still could learn. >>>>> >>>>> >I would be curious what gamma spectrometry the thing is >>>>> >carrying on board, too (if any, but likely so). Unlikely >>>>> >HPGe, but then who knows, Mars is a cold place, they may >>>>> >have figured some practical way to cool things down to >>>>> >about liquid nitrogen. >>>>> >>>>> Well, they certainly don't have much atmospheric pressure to >>>>> worry about. >>>>> >>>>> Which reminds me of another thing. How do they convect the >>>>> internally generated heat away. I recall hearing about >>>>> multiple power systems, operating around 32V at near 2A. More >>>>> than one. This power must be convected/conducted away -- no >>>>> way they want to radiate it. I wonder if they push it >>>>> (costing more heat) towards a vane or arm and drag it around >>>>> on the surface to get rid of it? >>>> >>>>The atmosphere won't help much. >>>> >>>>Why not? Thermal conductivity of air is pretty much constant till you >>>>get below 1 Torr or so. Wiki says the mean pressure on mars is about >>>>0.1 psi, which is ~5 torr. >>> >>>Good point. >>> >>>What triggered my comment is remembering that heat buildup >>>was most certainly a problem during broadcasts with the high >>>gain antenna system towards Earth. They can't operate it >>>continuously, if I recall correctly. Made me wonder about the >>>rest. I had also remembered the case of satellites and "knew" >>>that the Martian atmosphere could be as little as a few tens >>>of Pascals. So I projected that heat accumulation may be a >>>problem. Apparently, it isn't. >>> >>>I gather your point. To understand it more fully, I need to >>>think more closely about mean-free-path, I guess. Thanks. >>> >>>>Re spectrometer calibration: We had this "black body" source. (from >>>>Ortec?) That could be used for intensity calibration. PITA though. >>> >>>The problem for students is that they cannot afford the $800 >>>it takes to get a $8 tungsten bulb calibrated. (It can cost a >>>lot more than that, too.) Then they need to set up a careful >>>station for making the calibration. It's just plain too >>>expensive to do. And I don't know a way around it. Wavelength >>>calibration is CHEAP!! $12 buys a merc-argon calibration >>>lamp, which fires up with the Argon first (for about a minute >>>or two where you get some very nice Argon lines in the longer >>>wavelengths) and then the Mercury kicks in and dominates with >>>it's lines. A couple of well-timed snapshots and you've got >>>enough (with software) to completely calibrate your pixel >>>positions in a cheap ($10) megapixel camera. >>> >>>I'd LOVE to figure out a cheap intensity calibration setup, >>>though. So would a lot of other people, I suppose. >>> >>>>But maybe you could do something on the cheap with a tungsten light >>>>bulb. >>> >>>But that's the problem. I can get a cheap tungsten lamp. They >>>are VERY CHEAP. In fact, the EXACT SAME ONE I would buy, >>>calibrated, is dirt cheap uncalibrated. It is the calibration >>>data that comes with a newly calibrated lamp that costs so >>>darned much. It needs to be traceable to standards. And you >>>pay for that. Plus, you need an expensive power supply to >>>operate it (0.1% current control is standard.) And it ages, >>>too. Within 100 hours or so, it's drifted enough that it >>>needs recalibration. >>> >>>Thanks, >>>Jon >> >>It may be possible to start with a selection of calibrated LED sources >>(kind of like the near IR ones used for light source & light meter used >>for fiber optic cable measurements). With a nice selection of say a dozen >>wavelengths in the range of interest, it may become reasonably feasible. >>With a decent calibration cycle as well. >> >>Internet patent dated 7 August, 2012, all rights reserved. > >I know you were laughing. Don't. I wasn't. I thought it was an idea worth investigating, not necessarily the right approach to a solution. >I've been there. I've >already built calibration LEDs. Not for the purpose of >calibrating visible wavelength spectrophotometers, though. >They were very special-purpose standard-candle devices >because dispersion isn't anything like a tungsten lamp and >alignment of the LED die severely limits practical use. > >If you had ANY idea just how HARD it is to calibrate LEDs for >optical output.... That is why it is just a suggestion for a maybe workable approach. > >First, you buy 1000 LEDs and request that they all come from >the same FAB and batch. They will need to be operated at an >elevated, controlled temperature when they are finally used, >so you set each one up to run at that temperature and then >continuously observe them for 200 hours of operation. In that >time, most of them will drift all over the place and will NOT >settle down entirely in that time. You throw those away. Agreed. I have hit the drift wall a few times myself. Not fun. >Others will not drift all over but will drift way too fast to >be any good. Throw those away, too. Of the 10 or 15 LEDs left >in the batch that happen to have stabilized well enough in >200 hours of operation to appear to be useful, you go through >the trouble of cutting away the epoxy with precision tools >and then operating them some more while producing a >calibration table for each in their final module. Yep i was worried that it could be this bad. > >It's not cheap. Their wavelength skirts are wide, too. Now do >this for a variety of visible areas to produce what you are >talking about? > >Tungsten gives nice coverage. Here's a calibration table I >got from Optronix for a 45W tungsten lamp (actually a 50W), >model 245M, using a standard distance away using a standard >optical arrangement. Filament must be vertical, current >controlled to 0.1%, etc. It gives an example of how many >points are sometimes used, though you can always pay for >more. Given the black body curve behavior, interpolation at >different points is manageable. > >250,.000249 >270,.00818 >290,.00217 >300,.00332 >310,.00489 >320,.00697 >330,.00960 >340,.0130 >350,.0173 >370,.0285 >400,.0531 >450,.118 >500,.212 >555,.337 >600,.446 >654.6,.574 >700,.669 >800,.830 >900,.902 >1050,.892 >1100,.865 > >Jon Yep i have fought those curves as well. Tiresome but doable. You get the same kinds of thing is radiation dosing semiconductors (bipolar transistors mostly, measurements interest included 1/ H(fe), I(cbo), and a couple of others). Also combined radiation (includes annealing effect between the radiation types gamma vs neutron). ?-)
Technical Details
Message-ID:
<17t828he63ncjgk5nl6u65h3k80n98imgp@4ax.com>Path:
arc1-ca.pugleaf.net!c6ni115703407qas.0!nntp.google.com!border1.nntp.dca.giganews.com!border4.nntp.dca.giganews.com!border2.nntp.dca.giganews.com!nntp.giganews.com!nrc-news.nrc.ca!newsfeed.news.ucla.edu!usenet.stanford.edu!news.glorb.com!news.astraweb.com!border6.newsrouter.astraweb.com!not-for-mailReferences:
<fhpu1899csroivpfmno057i8dsdqoonbaa@4ax.com> <d2036554-ee03-42e5-a626-568b02d7cefe@j11g2000vbc.googlegroups.com> <odt028lhg82i08frth3ksbk0o02i0huet7@4ax.com> <cb387dcf-7d67-4a0e-820e-ca521cad6f4b@a9g2000vbn.googlegroups.com> <e0q228956bpb829qehome35ab6mcfoaps6@4ax.com> <5136b24c-3992-4de7-a0df-7864a64f7aaa@f2g2000vbm.googlegroups.com> <8nv2289qsb9f4hdm1gbltsqurbor5adgga@4ax.com> <onj3289imcj01qmca33u2o1o23fpk9bott@4ax.com> <3cm3281nv2ea98r39uj3nv38ton9s913i8@4ax.com>Show Full Headers
Complete Article Headers
X-Google-Thread: a5a6238865,7af901c0b69fae4
X-Google-Attributes: gida5a6238865,public,usenet
X-Google-NewGroupId: yes
X-Google-Language: ENGLISH,ASCII
Received: by 10.224.188.76 with SMTP id cz12mr12599307qab.0.1344999394839;
Tue, 14 Aug 2012 19:56:34 -0700 (PDT)
Path: arc1-ca.pugleaf.net!c6ni115703407qas.0!nntp.google.com!border1.nntp.dca.giganews.com!border4.nntp.dca.giganews.com!border2.nntp.dca.giganews.com!nntp.giganews.com!nrc-news.nrc.ca!newsfeed.news.ucla.edu!usenet.stanford.edu!news.glorb.com!news.astraweb.com!border6.newsrouter.astraweb.com!not-for-mail
From: josephkk <joseph_barrett@sbcglobal.net>
Newsgroups: sci.electronics.design,aus.electronics,comp.arch.embedded
Subject: Re: nasa-celebrates-successful-mars-landing
Date: Thu, 09 Aug 2012 19:52:37 -0700
Message-ID: <17t828he63ncjgk5nl6u65h3k80n98imgp@4ax.com>
References: <fhpu1899csroivpfmno057i8dsdqoonbaa@4ax.com> <d2036554-ee03-42e5-a626-568b02d7cefe@j11g2000vbc.googlegroups.com> <odt028lhg82i08frth3ksbk0o02i0huet7@4ax.com> <cb387dcf-7d67-4a0e-820e-ca521cad6f4b@a9g2000vbn.googlegroups.com> <e0q228956bpb829qehome35ab6mcfoaps6@4ax.com> <5136b24c-3992-4de7-a0df-7864a64f7aaa@f2g2000vbm.googlegroups.com> <8nv2289qsb9f4hdm1gbltsqurbor5adgga@4ax.com> <onj3289imcj01qmca33u2o1o23fpk9bott@4ax.com> <3cm3281nv2ea98r39uj3nv38ton9s913i8@4ax.com>
X-Newsreader: Forte Agent 6.00/32.1186
MIME-Version: 1.0
Lines: 232
Organization: Unlimited download news at news.astraweb.com
NNTP-Posting-Host: a78e8701.news.astraweb.com
X-Trace: DXC=lADDjZ1JjY_W]I=Ra]NaiPL?0kYOcDh@Z`<:;7PD^[hV3>m\XLHSD<ZFeK=h[\Ra]TEcG5O9_c[N_h1:?D;M88m^E]hH32>Ag5W8d`BJ3\ona^
Bytes: 11066
Content-Type: text/plain; charset=ISO-8859-1
Content-Transfer-Encoding: quoted-printable