Article #18Re: Any ideas for Air Flow Meter to operate at 2500psi ?
From: Mike
Date: Sun, 01 Aug 1999 00:00
Date: Sun, 01 Aug 1999 00:00
36 lines
2747 bytes
2747 bytes
In article <7o0lgo$qga$1@bgtnsc03.worldnet.att.net>, benmiller@worldnet.att.net says... >What flow rate range do you need to measure, and at what accuracy? Ah - ha - thats a good question ~`:o Anywhere from 0.1 to 20 Litres/min of equivalent atmospheric pressure, hence proportional to that mass flow at the higher pressures I'm interested in. I believe air mass (STP) is around 1.6g/m^3 therefore I'd be looking to measure the flow of 0.16mg to 320mg per minute at STP. Since the pressure can vary from 500psi to 5000psi then I'd be looking at minimum flow of around 0.16mg x 500/14.7 to a (high) maximum of 320mg x 5000/14.7 per minute, thats a dynamic range of about 5 decades ie 5 to about 100,000. Hence I'd be looking to resolve to 16 bits best case and 12bits worst case (since I will handle some scaling to bring down the dynamic range once I have settled on the best pressure range). Absolute accuracy need only be 5% at this stage to keep costs down but would like to achieve repeatability. Once I've decided on the best range of operation, then I expect I will only need to resolve to 12bits A to D and accuracy of about 2%. Response time to change in flow should be less than 5mS if at all possible. -- Rgds ~`:o) Mike Perth, Western Australia Mailto: <erazmus@wantree.com.au> 99% efficient RAPS charger, GMH Turbo with Twin tyres, surplus parts etc http://www.wantree.com.au/~erazmus Some say there is no magic but, all things begin with thought then it becomes academic, then some poor slob works out a practical way to implement all that theory, this is called Engineering - for most people another form of magic. " ...mmm thats because the laws of physics exceed the boundaries of the contractual agreement (and the money ain't enough either)... "
Technical Details
Message-ID:
<7o0n7q$fm2$1@centipede.wantree.com.au>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<7numbj$hol$1@centipede.wantree.com.au> <7o0lgo$qga$1@bgtnsc03.worldnet.att.net>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 113e16,80dcc9b33c437f55 X-Google-Attributes: gid113e16,public X-Google-Thread: 115730,80dcc9b33c437f55 X-Google-Attributes: gid115730,public X-Google-Thread: 103407,80dcc9b33c437f55 X-Google-Attributes: gid103407,public X-Google-Thread: 108659,b8749223290ba71d X-Google-Attributes: gid108659,public X-Google-Thread: 100492,80dcc9b33c437f55 X-Google-Attributes: gid100492,public From: erazmus@wantree.com.au (Mike) Subject: Re: Any ideas for Air Flow Meter to operate at 2500psi ? Date: 1999/08/01 Message-ID: <7o0n7q$fm2$1@centipede.wantree.com.au> X-Deja-AN: 507531905 References: <7numbj$hol$1@centipede.wantree.com.au> <7o0lgo$qga$1@bgtnsc03.worldnet.att.net> Content-Type: Text/Plain; charset=US-ASCII Organization: Network Power Systems Mime-Version: 1.0 Newsgroups: sci.electronics.equipment,aus.electronics,alt.energy.homepower,aus.ads.wanted,aus.cars