Article View: sci.electronics.equipment
Article #21Re: Any ideas for Air Flow Meter to operate at 2500psi ?
From: Warren Lauzon
Date: Sun, 01 Aug 1999 00:00
Date: Sun, 01 Aug 1999 00:00
58 lines
3558 bytes
3558 bytes
FCI has some that will do it, but don't expect to get one cheap. Last time we got one, it was in the $1500 range. http://www.fluidcomponents.com/ -- ---------------------------------------------------------- Electricity from the sun since 1979 www.windsun.com www.solar-electric.com (online store) ---------------------------------------------------------- Mike <erazmus@wantree.com.au> wrote in message news:7o0n7q$fm2$1@centipede.wantree.com.au... > In article <7o0lgo$qga$1@bgtnsc03.worldnet.att.net>, > benmiller@worldnet.att.net says... > > >What flow rate range do you need to measure, and at what accuracy? > > Ah - ha - thats a good question ~`:o > > Anywhere from 0.1 to 20 Litres/min of equivalent atmospheric pressure, hence > proportional to that mass flow at the higher pressures I'm interested in. > I believe air mass (STP) is around 1.6g/m^3 therefore I'd be looking to > measure the flow of 0.16mg to 320mg per minute at STP. Since the pressure > can vary from 500psi to 5000psi then I'd be looking at minimum flow of > around 0.16mg x 500/14.7 to a (high) maximum of 320mg x 5000/14.7 per minute, > thats a dynamic range of about 5 decades ie 5 to about 100,000. Hence I'd be > looking to resolve to 16 bits best case and 12bits worst case (since I > will handle some scaling to bring down the dynamic range once I have settled > on the best pressure range). Absolute accuracy need only be 5% at this stage > to keep costs down but would like to achieve repeatability. > > Once I've decided on the best range of operation, then I expect I will only > need to resolve to 12bits A to D and accuracy of about 2%. > > Response time to change in flow should be less than 5mS if at all possible. > > -- > Rgds ~`:o) > Mike > Perth, Western Australia > Mailto: <erazmus@wantree.com.au> > 99% efficient RAPS charger, GMH Turbo with Twin tyres, surplus parts etc > http://www.wantree.com.au/~erazmus > Some say there is no magic but, all things begin with thought then it becomes > academic, then some poor slob works out a practical way to implement all that > theory, this is called Engineering - for most people another form of magic. > " ...mmm thats because the laws of physics exceed the boundaries of the > contractual agreement (and the money ain't enough either)... " >
Technical Details
Message-ID:
<7o2cc0$fag$1@bgtnsc02.worldnet.att.net>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<7numbj$hol$1@centipede.wantree.com.au> <7o0lgo$qga$1@bgtnsc03.worldnet.att.net> <7o0n7q$fm2$1@centipede.wantree.com.au>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 108659,b8749223290ba71d X-Google-Attributes: gid108659,public X-Google-Thread: 115730,80dcc9b33c437f55 X-Google-Attributes: gid115730,public X-Google-Thread: 103407,80dcc9b33c437f55 X-Google-Attributes: gid103407,public X-Google-Thread: 113e16,80dcc9b33c437f55 X-Google-Attributes: gid113e16,public X-Google-Thread: 100492,80dcc9b33c437f55 X-Google-Attributes: gid100492,public From: "Warren Lauzon" <wlauzon@worldnet.att.net> Subject: Re: Any ideas for Air Flow Meter to operate at 2500psi ? Date: 1999/08/01 Message-ID: <7o2cc0$fag$1@bgtnsc02.worldnet.att.net> X-Deja-AN: 507719202 References: <7numbj$hol$1@centipede.wantree.com.au> <7o0lgo$qga$1@bgtnsc03.worldnet.att.net> <7o0n7q$fm2$1@centipede.wantree.com.au> X-Priority: 3 X-MimeOLE: Produced By Microsoft MimeOLE V5.00.2314.1300 X-Complaints-To: abuse@worldnet.att.net X-Trace: bgtnsc02.worldnet.att.net 933541056 15696 12.72.34.32 (1 Aug 1999 20:57:36 GMT) Organization: Northern Arizona Wind & Sun X-MSMail-Priority: Normal NNTP-Posting-Date: 1 Aug 1999 20:57:36 GMT Newsgroups: sci.electronics.equipment,aus.electronics,alt.energy.homepower,aus.ads.wanted,aus.cars