>In article <463@sunpix.East.Sun.COM> cram@sunpix.east.sun.com (Marc W. Howard) writes:
>-> Is there a way to use the X-10 three way switch in a 4-way (i.e.,
>->three or more switch controlled) circuit? I have one such circuit in my
>->house that I'd like to control. I notice that you can buy the non-active
>->half of the three way switch pair as a separate item; does this imply
>->that there is a way to use two of them and the three-way master switch in
>->a four way circuit?
This may seem like an odd response, but do you need one used as a 4-way?
Let's look at this schematically...(assuming ASCII is capable of rendering
schematics...)
hot o-----o o-------o o-----o o------o
~ ------/ X X X \-------,
o-----o o-------o o-----o o------o |
120 ^ ^ ^ ^ ^ (load)
VAC 3-way 4-way 4-way 4-way 3-way |
|
~ -------------------------------------------------'
neutral
Each 4-way switch consists of a DPTD switch wired the following way:
.---------,
| |
>------o o ,--o `----->
from 3-way `----/-. to next 3-way
,---' \
>------o o o .----->
| |
`---------'
(This crude drawing is supposed to represent the wires from the first 3-way
being crossed and connected to the other pair of contacts in the switch.)
Since this is the way a typical n-way switching circuit is wired, what
happens if you replace either one of the 3-way switches with an X-10
controlled device? You have remote control. Toggling any *one* of
the above switches controls the load. I don't understand why you would
need remote control of more than one switch to perform only the one
function; or why you would specifically have to use X10 to control one
of the 4-ways.
I'm sorry if I missed your point, but I am not sure what your specific
application is (if it's not this).
-j
--
J. Deters
INTERNET: jad@dayton.DHDSC.MN.ORG ATT: 612-375-3116
UUCP: ...!bungia!dayton!jad USPS: 700 Nicollet Mall/MIS 1060
ICBM: 44^58'36"N by 93^16'14"W Minneapolis, MN 55402
Technical Details
Message-ID:
<7683@dayton.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!censor!geac!torsqnt!lethe!yunexus!ists!helios.physics.utoronto.ca!news-server.csri.toronto.edu!cs.utexas.edu!sdd.hp.com!caen!uwm.edu!uwvax!ub.d.umn.edu!cs.umn.edu!dayton!jadReferences:
<463@sunpix.East.Sun.COM> <7523@exodus.Eng.Sun.COM>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!censor!geac!torsqnt!lethe!yunexus!ists!helios.physics.utoronto.ca!news-server.csri.toronto.edu!cs.utexas.edu!sdd.hp.com!caen!uwm.edu!uwvax!ub.d.umn.edu!cs.umn.edu!dayton!jad From: jad@dayton.UUCP (J. Deters) Newsgroups: sci.electronics Subject: Re: X-10 switches used in 4-way circuit Summary: Use at one end only... Keywords: X-10 Message-ID: <7683@dayton.UUCP> Date: 9 Feb 91 05:27:42 GMT References: <463@sunpix.East.Sun.COM> <7523@exodus.Eng.Sun.COM> Reply-To: jad@dayton.DHDSC.MN.ORG (J. Deters) Organization: Department Store Division of DHC Lines: 54