Article View: sci.electronics
Article #14245Re: 220V/120V transformers with 60Hz/50Hz converters
From: Bob Myers
Date: Wed, 12 Jun 1991 19:04
Date: Wed, 12 Jun 1991 19:04
16 lines
1351 bytes
1351 bytes
>usually, referring mainly to linear power supplies. Don't even think
>about doing this with switching power supplies...
Doing what? Operating on 50 Hz AC? It's the rare switcher that isn't designed
to work on both 50 Hz and 60 Hz AC - "usually," the power supply manufacturer
is designing to some range which will cover both standard frequencies plus
a generous tolerance; like "47-63 Hz." Why do you think that switchers are
especially sensitive to line frequency? (Not that you can't come up with
a particular switcher that won't work at 50 Hz with X load, but your reply
seemed to imply that switchers were designed for a *very* limited range of
input frequencies.)
Bob Myers KC0EW HP Graphics Tech. Div.| Opinions expressed here are not
Ft. Collins, Colorado | those of my employer or any other
myers@fc.hp.com | sentient life-form on this planet.
Technical Details
Message-ID:
<17660171@hpfcrlm.HP.COM>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!rpi!think.com!sdd.hp.com!hplabs!hpfcso!hpfcdj!hpfcrlm!myersReferences:
<1991Jun3.021343.24148@athena.mit.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!rpi!think.com!sdd.hp.com!hplabs!hpfcso!hpfcdj!hpfcrlm!myers From: myers@hpfcrlm.HP.COM (Bob Myers) Newsgroups: sci.electronics Subject: Re: 220V/120V transformers with 60Hz/50Hz converters Message-ID: <17660171@hpfcrlm.HP.COM> Date: 12 Jun 91 19:04:47 GMT References: <1991Jun3.021343.24148@athena.mit.edu> Organization: Hewlett Packard -- Fort Collins, CO Lines: 16