ESD is nasty stuff. Don't forget that as well as the arc when static jumps it also carries a field; this is probably what is locking up your macjhine. A typical buildup on carpets is in the 12Kv region and vinyl tile is around 4Kv. Both direct injection (discharge) and ehnhanced field produce a double exponential pulse. The peak cuurrent for a discharge at 12Kv is in the area of 8 amps; the field can produce a peak current of up to 22 amps. I don't know what's in your keyboard but I'd bet the pulses are seytting up an undefined condition that you reset by powering down. when you unplug the keyboard. Eventually the machine will probably fail if you don't control the static; bipolar devices will burn or melt due to the current and MOS will melt when the voltage is high enough to puncture the oxide layer. BTW the duration of a stsatic pulse is in the area of 50 to 150 nanoseconds. Bob.
Technical Details
Message-ID:
<77230002@teecs.UUCP>Path:
arc1-ca.pugleaf.net!sparky!uunet!olivea!spool.mu.edu!uwm.edu!cs.utexas.edu!torn!utzoo!censor!teecs!smithrReferences:
<1992Dec10.001559.1608@miavx2.ham.muohio.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!olivea!spool.mu.edu!uwm.edu!cs.utexas.edu!torn!utzoo!censor!teecs!smithr From: smithr@teecs.UUCP (Robert Smith) Newsgroups: sci.electronics Subject: Re: Static electricty problem Message-ID: <77230002@teecs.UUCP> Date: 15 Dec 92 18:47:13 GMT References: <1992Dec10.001559.1608@miavx2.ham.muohio.edu> Organization: Litton Systems, Toronto ONT Lines: 15