Article View: sci.electronics
Article #15450Re: Basic bench equipment query
From: Ylo Mets
Date: Sun, 27 Dec 1992 17:24
Date: Sun, 27 Dec 1992 17:24
28 lines
1764 bytes
1764 bytes
jeh@cmkrnl.com wrote:
> I'll second this, and LOUDLY, too.
> It appalls me to see frequency counters (and instruments like DMMs that include
> counters) that have no trigger level control, no input coupling selector (AC or
> DC), no edge selector (rising or falling). You wouldn't buy a triggered-sweep
> scope without such controls; of what possible use is a counter without them?
> --- Jamie Hanrahan, Kernel Mode Consulting, San Diego CA
> Internet: jeh@cmkrnl.com, hanrahan@eisner.decus.org, or jeh@crash.cts.com
> Uucp: ...{crash,eisner,uunet}!cmkrnl!jeh
To be more specific, Fluke 87 has some choices for triggering:
on 400 mV ac range about 150 mV sensitivity, no offset,
on dc ranges the trigger level is about 10% of the range,
except for the 4 Vdc, which is meant for TTL with 1.7 V
threshold. One can even choose rising or falling edge.
It should also work on current measurement ranges.
I agree with the opinion that a counter cannot be used to
determine the waveform, one can measure the frequency of a
known waveform with much higher accuracy than a scope allows.
In case of slightest suspicion in the readings of a counter
you need an oscilliscope.
Ylo Mets.
Technical Details
Message-ID:
<1hkosoINNivo@osiris.kbfi.ee>Path:
arc1-ca.pugleaf.net!sparky!uunet!van-bc!cs.ubc.ca!destroyer!gumby!yale!yale.edu!think.com!enterpoop.mit.edu!eru.mt.luth.se!lunic!sunic!osiris.kbfi.ee!osiris.kbfi.ee!not-for-mailReferences:
<1992Dec27.030536.1024@cmkrnl.com>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!van-bc!cs.ubc.ca!destroyer!gumby!yale!yale.edu!think.com!enterpoop.mit.edu!eru.mt.luth.se!lunic!sunic!osiris.kbfi.ee!osiris.kbfi.ee!not-for-mail From: ylo@osiris.kbfi.ee (Ylo Mets) Newsgroups: sci.electronics Subject: Re: Basic bench equipment query Message-ID: <1hkosoINNivo@osiris.kbfi.ee> Date: 27 Dec 92 17:24:40 GMT References: <1992Dec27.030536.1024@cmkrnl.com> Organization: Institute of Chemical Physics and Biophysics, Estonia Lines: 28 NNTP-Posting-Host: osiris.kbfi.ee X-Newsreader: TIN [version 1.1 PL8]