Re: Transmission line question

#15932
From: Gerald Vernon Nelson
Date: Mon, 21 Dec 1992 03:39
14 lines
1129 bytes
In <1992Dec15.202004.15878@ucsu.Colorado.EDU> barr@tramp.Colorado.EDU (BARR DOUG) writes:

>Some specs I have call for ethernet coax to be grounded in one location
>and one location only! I am wondering why this is. Antenna effects,
>current loops or something else. Does anyone know why this is the case?


Ground loops.  If you grounded a piece of coax at two ends of a building,
the grounds may not be at the same potential.

If you check, you will find that the BNC connectors are not connected
to the chassis of the P.C.  The whole line is grounded at one point.

Vern Nelson
Technical Details
Message-ID: <BzLBIA.7vM@ccu.umanitoba.ca>
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!cs.utexas.edu!sun-barr!olivea!charnel!sifon!newsflash.concordia.ca!mizar.cc.umanitoba.ca!vnelson
References: <1992Dec15.202004.15878@ucsu.Colorado.EDU>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!cs.utexas.edu!sun-barr!olivea!charnel!sifon!newsflash.concordia.ca!mizar.cc.umanitoba.ca!vnelson
From: vnelson@ccu.umanitoba.ca (Gerald Vernon Nelson)
Newsgroups: sci.electronics
Subject: Re: Transmission line question
Message-ID: <BzLBIA.7vM@ccu.umanitoba.ca>
Date: 21 Dec 92 03:39:46 GMT
References: <1992Dec15.202004.15878@ucsu.Colorado.EDU>
Sender: news@ccu.umanitoba.ca
Organization: University of Manitoba, Winnipeg, Canada
Lines: 14
Nntp-Posting-Host: ccu.umanitoba.ca