bordy@edy.elettra.trieste.it (Luca Giovanetti Sismat Genova) writes:
> is there anybody that can say anything about Excellon file format
>for plotter drill ?
It's not very complicated. Here's part of one.
M48
T01F00S00
T02F00S00
T03F00S00
T04F00S00
T05F00S00
T06F00S00
T07F00S00
%
T01
X029Y018
X02Y015
X039Y019
X023Y015
X02Y014
X039Y018
...
The first part describes the "tools", the drills being used
(you have to provide a tool list separately), and then we see the holes
being specified, with the tool number ("T01") and the hole locations
"X029Y018". That's the general idea.
Most CAD systems for laying out printed circuit boards will produce
a drill file.
John Nagle
Technical Details
Message-ID:
<1993Jan28.083117.4939@netcom.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!olivea!spool.mu.edu!howland.reston.ans.net!usc!elroy.jpl.nasa.gov!decwrl!csus.edu!netcom.com!nagleReferences:
<1993Jan26.132454.698@cine88.cineca.it>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!olivea!spool.mu.edu!howland.reston.ans.net!usc!elroy.jpl.nasa.gov!decwrl!csus.edu!netcom.com!nagle From: nagle@netcom.com (John Nagle) Newsgroups: sci.electronics Subject: Re: Excellon PCB drilling standard Message-ID: <1993Jan28.083117.4939@netcom.com> Date: 28 Jan 93 08:31:17 GMT References: <1993Jan26.132454.698@cine88.cineca.it> Organization: Netcom - Online Communication Services (408 241-9760 guest) Lines: 33