Article View: sci.electronics
Article #18580Re: Running 120V AC equipment off 240V AC.
From: Henry Schaffer
Date: Thu, 11 Feb 1988 01:28
Date: Thu, 11 Feb 1988 01:28
29 lines
1969 bytes
1969 bytes
In article <204@unh.UUCP>, abc@unh.UUCP (Avinash B Chopde) writes:
>
> A question about stepping down voltage.
>
> I went into a Radio Shack shop to get a transformer (primary 240V,
^^^^^^^^^^^
> secondary 120V) so that 120V equipment can be run off 240V AC supply.
>
> I thought only the wattage should be important in such a transformer,
^^^^^^^^^^^
> but the salesman told me that the 1000W unit they have will work only for
> hair-dryers, and cannot be used for motors (food processors, etc) even if
> they are of lesser wattage.
The problem is that everyone concerned seems to be assuming that a
240->120 volt converter has to be a transformer. A transformer does work
fine and can run anything, but tends to be big and expensive in the high
current/wattage sizes.
For much less money and in a much smaller package you can put a
half-wave rectifier rectifier which will give you the same effect - *for
loads which don't care about the wave-form*. Note that this generally
includes resistive loads (such as heaters - which is where the high
wattage is important) - but doesn't generally include audio equipment.
Some motors will work, others won't (vagueness intentional :-).
> ...
> =================================
> Avinash Chopde (abc@unhcs.CSNET)
> =================================
--henry schaffer n c state univ
Technical Details
Message-ID:
<4591@ecsvax.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!uunet!husc6!bloom-beacon!gatech!mcnc!ecsvax!hesReferences:
<204@unh.UUCP>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!mnetor!uunet!husc6!bloom-beacon!gatech!mcnc!ecsvax!hes From: hes@ecsvax.UUCP (Henry Schaffer) Newsgroups: sci.electronics Subject: Re: Running 120V AC equipment off 240V AC. Message-ID: <4591@ecsvax.UUCP> Date: 11 Feb 88 01:28:46 GMT References: <204@unh.UUCP> Organization: NC State Univ. Lines: 29 Keywords: step-down transformer, resistive/inductive loads Summary: voltage converters aren't always transformer (the non-transformer ones can't be used with everything)