In article <4496@husc6.harvard.edu>, kiely@lownlab.harvard.edu (James P. Kiely) writes:
> Given that toroid power transformers are lighter, more efficient,
> and generate a smaller spurious magnetic field than the more
> traditional stacked pole transformers, why doesn't everyone use toroids?
In general, two reasons:
1. Toroids cost much more to manufacture than comventional
transformers with E-type or U-type laminations.
2. Toroids become quite impracticable to use for power ratings
(at 60 Hz) beyond, say about 1 KVA. The diameter becomes
large, along with the concurrent difficulties in winding
long lengths of heavier gauge wire.
To get some idea of the problems in manufacturing "larger"
transformers, take a look at a toroidal coil winder some day.
<> Larry Lippman @ Recognition Research Corp., Clarence, New York
<> UUCP: {allegra|ames|boulder|decvax|rutgers|watmath}!sunybcs!kitty!larry
<> VOICE: 716/688-1231 {hplabs|ihnp4|mtune|utzoo|uunet}!/
<> FAX: 716/741-9635 {G1,G2,G3 modes} "Have you hugged your cat today?"
Technical Details
Message-ID:
<2498@kitty.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!uunet!kitty!larryReferences:
<4496@husc6.harvard.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!mnetor!uunet!kitty!larry From: larry@kitty.UUCP (Larry Lippman) Newsgroups: sci.electronics Subject: Re: toroid vs. stacked pole transformers Message-ID: <2498@kitty.UUCP> Date: 29 Apr 88 21:37:27 GMT References: <4496@husc6.harvard.edu> Organization: Recognition Research Corp., Clarence, NY Lines: 22 Keywords: toroid transformer Summary: Cost and maximum power output...