Re: Finding an electrically-controlled valve?

#20439
From: Larry Lippman
Date: Tue, 17 Jan 1989 04:36
45 lines
3274 bytes
In article <1989Jan15.035721.14156@utzoo.uucp>, henry@utzoo.uucp (Henry Spencer) writes:
> >	Since the above are all solenoid valves, a position encoder is
> >not required...
> 
> Unless, of course, you want to be sure that the valve has really
> operated when you ask it to, which is usually considered necessary
> in critical control systems.  (If you don't think controlling a
> shower justifies this degree of reliability, consider the consequences
> of turning off cold but not hot in a place with an enthusiastic water
> heater -- non-trivial injury might result.)

	A "reliable" system design would still never trust the valve (and
consequently its position) - it would measure the actual temperature of
the mixed water, which is ultimately the bottom line.

> I think the original poster wanted proportional control rather than just
> on/off, which is why he specified that solenoid valves weren't of interest.
> Short of the (plausible) suggestion of building a 4-bit hydraulic DAC with
> four valves, it looks to me like he's going to need something like a
> motor-controlled needle valve, not normally a consumer item, except perhaps
> in some fancy washing machine.  He'll also need a separate shutoff valve,
> since needle valves aren't usually designed to reduce flow to zero.

	Needle valves are available for process control use which have an
effective shutoff position.  From an idealistic standpoint, a rotary valve
is a poor choice for proportional control applications, since by its very
nature the ON<->OFF transition is only 90 degrees of rotation.  An example of
a suitable valve is a bellows-type valve which uses, in effect, a needle and
seat arrangement; the position of the bellows can be controlled via an
electric motor drive, electromagnet (for small valves, at least), or air
pressure supplied by an I/P transducer (common in industrial applications).

	One _can_ achieve decent proportional control with just a hot and
cold water solenoid valve.  In our darkroom, we have a Wing-Lynch electronic
water temperature controller which uses two solenoid valves; this unit
provides an accuracy of +/- 0.1 deg F.  The electronic circuit monitors
output temperature and _pulses_ the valves accordingly.  The key to effective
control in this arrangement is to have a mixing chamber (can be just a coiled
length of tubing) to mix the hot and cold water BEFORE the output temperature
is measured.

<>  Larry Lippman @ Recognition Research Corp., Clarence, New York
<>  UUCP:  {allegra|ames|boulder|decvax|rutgers|watmath}!sunybcs!kitty!larry
<>  VOICE: 716/688-1231          {att|hplabs|mtune|utzoo|uunet}!/
<>  FAX:   716/741-9635 {G1,G2,G3 modes}   "Have you hugged your cat today?" 
Technical Details
Message-ID: <2936@kitty.UUCP>
Path: arc1-ca.pugleaf.net!utzoo!attcan!uunet!lll-winken!ames!hc!pprg.unm.edu!unmvax!ncar!boulder!sunybcs!kitty!larry
References: <1404@accelerator.eng.ohio-state.edu> <2925@kitty.UUCP> <1989Jan15.035721.14156@utzoo.uucp>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!uunet!lll-winken!ames!hc!pprg.unm.edu!unmvax!ncar!boulder!sunybcs!kitty!larry
From: larry@kitty.UUCP (Larry Lippman)
Newsgroups: sci.electronics
Subject: Re: Finding an electrically-controlled valve?
Summary: Proportional control is possible with solenoid valves
Message-ID: <2936@kitty.UUCP>
Date: 17 Jan 89 04:36:31 GMT
References: <1404@accelerator.eng.ohio-state.edu> <2925@kitty.UUCP> <1989Jan15.035721.14156@utzoo.uucp>
Organization: Recognition Research Corp., Clarence, NY
Lines: 45