Re: Negative ion generators

#22581
From: GregS
Date: Thu, 12 Sep 2002 20:44
35 lines
3257 bytes
In article <f7d9a152.0209121216.799e7e53@posting.google.com>, jason_hsu@my-deja.com (Jason Hsu) wrote:
>Exactly what voltage and current levels do I need? 
>
>I would like to build a negative ion generator. From what I
>understand, a negative ion generator has a very high voltage
>(thousands) and a very low current. This voltage is fed into a
>very-high-voltage diode (oriented to pass the negative voltage but
>reject the positive voltage). The resulting very high negative voltage
>is fed into a very sharp object (such as a sewing needle), which
>injects the negative ions into the air inside the chassis. A nearby
>fan disperses the negative ions into the air in the room outside the
>chassis.
>
>Exactly what voltage and current levels do I need? (I also realize
>that I must simulate this in PSPICE, because the tiny current levels
>and huge voltage levels aren't in a range that regular multimeters can
>handle.) I have heard that using too much power will produce ozone,
>which is poisonous.

Emulate? A good potential is 6-9KV. Current is microamps, maybe
50-500 depending on the emitters and grounds nearby. A DC source is needed.
However which way you do it, diode, diodes. Negative of the supply goes
to the emitters, needles, wire brush, etc. The positive terminal gets 
referenced to AC ground. Its a good idea or necessary to add series 
resistance, so a finger on needle will get less than 1 Ma. preferably less 
than 500 microAmps. A fan is unecessary. It blows air anyway. A fan
can be used to force surrounding air through and land upon a slighty
conductive element or just metal. The debris just sticks to all you walls
otherwise. It will do it anyway. If the voltage is too high or a ground is
too close to the needles, an arc can try to occur which will produce
Ozone. Ozone needs carefull attention but is an otherwise
excellant odor eliminator, preferably used in an unoccupied space,
or while you are away. You like the smell of the sun through a window?
Ion generators can reduce odors slightly.
greg
Technical Details
Message-ID: <alqu5t$73q$2@usenet01.srv.cis.pitt.edu>
Path: arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!newsfeed.stanford.edu!logbridge.uoregon.edu!snoopy.risq.qc.ca!newsflash.concordia.ca!pitt.edu!zipp-vav6hxhozs
References: <f7d9a152.0209121216.799e7e53@posting.google.com>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: 112d1e,bf0b2e512c12af46
X-Google-Attributes: gid112d1e,public
X-Google-Thread: 10d137,bf0b2e512c12af46
X-Google-Attributes: gid10d137,public
X-Google-Thread: 105d97,bf0b2e512c12af46
X-Google-Attributes: gid105d97,public
X-Google-Thread: 103407,bf0b2e512c12af46
X-Google-Attributes: gid103407,public
X-Google-ArrivalTime: 2002-09-12 13:41:34 PST
Path: arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!newsfeed.stanford.edu!logbridge.uoregon.edu!snoopy.risq.qc.ca!newsflash.concordia.ca!pitt.edu!zipp-vav6hxhozs
From: szekeresREMOVE@pitt.edu (GregS)
Newsgroups: sci.electronics,sci.electronics.design,aus.electronics,alt.engineering.electrical
Subject: Re: Negative ion generators
Date: Thu, 12 Sep 2002 20:44:37 GMT
Organization: Why?
Lines: 35
Message-ID: <alqu5t$73q$2@usenet01.srv.cis.pitt.edu>
References: <f7d9a152.0209121216.799e7e53@posting.google.com>
NNTP-Posting-Host: electronic2.cbp.pitt.edu
X-Trace: usenet01.srv.cis.pitt.edu 1031863293 7290 136.142.52.106 (12 Sep 2002 20:41:33 GMT)
X-Complaints-To: usenet@imap.pitt.edu
NNTP-Posting-Date: Thu, 12 Sep 2002 20:41:33 +0000 (UTC)
X-Newsreader: News Xpress 2.01