In article <z2zt1ta@rpi.edu> richtt@aix.rpi.edu (Timothy G. Richter) writes:
>
>So far, everyone has mentioned neon sign transformers.  What about fluorescent
>ballasts, as they are high voltage step-up transformers, also?
>
They are not transformers; they are current-limiting inductors.  Fluorescent
lights work at 120 volts with heated cathodes.  The cathodes are heated
initially like heating elements, and are then kept warm by the current
through the bulb.



-- 
==========================================================================