Phone line monitor

#442
From: X1FT
Date: Tue, 03 Nov 1992 21:07
25 lines
1791 bytes
Greetings,
 
I am installing the second phase of a house alarm system, and among other
things, I want to report on the failure of a phone line.  After looking up
the various voltages and polarities that exist depending on the status
of the phone (on hook, off hook, ringing, etc), it seems that the simplest
approach is to connect ring and tip to the to AC legs of a full wave
bridge rectifier, then series a resistor (say 1k) with a small capacitor
(say .5uf) across the DC legs, and monitor the voltage across the cap.
Oops, add a 10k resistor across the cap to drain the charge, but not enough
to load the phone line.  When it goes to zero, the phone company is no longer
on the other end of the line.
 
Obviously, I want the existing phones to continue working as before, and this
unit should not add any appreciable load to the phone line.
 
Am I missing something?  This seems simple enough to set up tonite.
Comments?  Thank you all - this list is an *excellent* technical reference!
                                - Frank
*************************************************************************
Frank Tompkins           ΒΊ   Internet: X1FT@VM1.CC.UAKRON.EDU
University of Akron      ΒΊ
Akron, Ohio   44325-3501 ΒΊ
  "I have not failed, I've just found 10,000 ways that won't work"
                                                     - Thomas Edison
Technical Details
Message-ID: <16894F0EE.X1FT@VM1.CC.UAKRON.EDU>
Path: arc1-ca.pugleaf.net!sparky!uunet!news.encore.com!csar!foxtail!sdd.hp.com!saimiri.primate.wisc.edu!ames!agate!usenet.ins.cwru.edu!news.uakron.edu!VM1.CC.UAKRON.EDU!X1FT

Show Full Headers
Complete Article Headers
Newsgroups: sci.electronics
Path: arc1-ca.pugleaf.net!sparky!uunet!news.encore.com!csar!foxtail!sdd.hp.com!saimiri.primate.wisc.edu!ames!agate!usenet.ins.cwru.edu!news.uakron.edu!VM1.CC.UAKRON.EDU!X1FT
From: X1FT@VM1.CC.UAKRON.EDU
Subject: Phone line monitor
Message-ID: <16894F0EE.X1FT@VM1.CC.UAKRON.EDU>
Sender: news@news.uakron.edu
Organization: The University of Akron
Date: Tue, 3 Nov 1992 21:07:58 GMT
Lines: 25