🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: sci.electronics
Article #480

Re: How to electronically detect X-RAYS???

#480
From: Allen Wallace
Date: Wed, 04 Nov 1992 17:37
16 lines
1223 bytes
In article <1992Oct31.170935.1393@cactus.org> Charles Thompson,
thompson@cactus.org writes:
>I am looking for a sensitive X-ray detector.
>What is the best way to detect X-rays?

Another idea that comes to mind is to use neon bulbs. Neon lamps need
a photon or gamma ray to start the bulb. Some bulbs have a small amount
of radioactive "starter". Just put the bulb in a relaxation oscillator,
and
the flash rate should indicate light or gamma ray levels. You can use old
NIXIE neon tubes for more sensitivity because of their increased volume.
-- 
---
root	                               root@dtint.dtint.com
Digital Technology Int.                (801)226-2984	
500 W. 1200 South, Orem UT, 84057      FAX (801) 226-8438
Technical Details
Message-ID: <1992Nov4.173740.4219@dtint.uucp>
Path: arc1-ca.pugleaf.net!sparky!uunet!dtint!usenet
References: <1992Oct31.170935.1393@cactus.org>

Show Full Headers
Complete Article Headers
Newsgroups: sci.electronics,sci.space,sci.space.shuttle,sci.physics
Path: arc1-ca.pugleaf.net!sparky!uunet!dtint!usenet
From: Allen Wallace <allen@dtint.dtint.com>
Subject: Re: How to electronically detect X-RAYS???
Message-ID: <1992Nov4.173740.4219@dtint.uucp>
X-Xxdate: Wed, 4 Nov 92 10:37:10 GMT
Sender: usenet@dtint.uucp
Organization: Digital Technology International
X-Useragent: Nuntius v1.1.1d9
References: <1992Oct31.170935.1393@cactus.org>
Date: Wed, 4 Nov 92 17:37:40 GMT
Lines: 16