Re: Help with Fluke 4000A DMM

#5303
From: Ed Ferguson
Date: Fri, 27 Jul 1990 15:48
10 lines
1049 bytes
In article <27498@netnews.upenn.edu>, depolo@eniac.seas.upenn.edu (Jeff DePolo) writes:
> I have a Fluke 4000A digital multimeter that I got at a hamfest.
> Taking the cover off reveiled a broken filiment in a light bulb ...

I'm sure you mean model 8000A since Fluke never made a model 4000A.
The bulb is a General Electric 63.  It is 7 volts, 630 mA, bayonet base.
If you cannot find one call Fluke Service Parts at 800-526-4731.  They
will take credit card orders. The Fluke part number is 352237.