To Gary, who owns the ICF-2010 with the potentially 'hot' chassis --
Several electronics products connect each leg (hot and neutral) of the
AC line to the chassis/green-wire ground with "Y" capacitors to reduce
conducted EMI. If a product like this isn't grounded (i.e. the green-wire
ground is broken at any point), the capacitors divide the AC line voltage
in half and the chassis floats at half line voltage (65v).
I consider a 'buzz' from any equipment pretty serious, and I recommend
tracking down and fixing the cause of the problem.
Good luck,
Carl "nearly killed by a 'grounded' drill once" Wuebker
clw@hprnd * HP Roseville Networks Division * (916) 785-4296
Technical Details
Message-ID:
<1100001@hprnd.HP.COM>Path:
arc1-ca.pugleaf.net!utzoo!attcan!utgpu!jarvis.csri.toronto.edu!rutgers!apple!motcsd!hpda!hpcupt1!hprnd!clwReferences:
<89Jun8.160452edt.10877@ephemeral.ai.toronto.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!utgpu!jarvis.csri.toronto.edu!rutgers!apple!motcsd!hpda!hpcupt1!hprnd!clw From: clw@hprnd.HP.COM (Carl Wuebker) Newsgroups: sci.electronics Subject: Re: Touching a "hot" connector Message-ID: <1100001@hprnd.HP.COM> Date: 19 Jun 89 20:59:05 GMT References: <89Jun8.160452edt.10877@ephemeral.ai.toronto.edu> Organization: HP Roseville Networks Division Lines: 15