Re: Touching a "hot" connector

#593
From: Carl Wuebker
Date: Mon, 19 Jun 1989 20:59
15 lines
1104 bytes
     To Gary, who owns the ICF-2010 with the potentially 'hot' chassis --

     Several electronics products connect each leg (hot and neutral) of the 
AC line to the chassis/green-wire ground with "Y" capacitors to reduce 
conducted EMI.  If a product like this isn't grounded (i.e. the green-wire
ground is broken at any point), the capacitors divide the AC line voltage
in half and the chassis floats at half line voltage (65v).  

     I consider a 'buzz' from any equipment pretty serious, and I recommend
tracking down and fixing the cause of the problem.

Good luck,
   Carl "nearly killed by a 'grounded' drill once" Wuebker 
   clw@hprnd * HP Roseville Networks Division * (916) 785-4296