In article <BuAB37.6I6@suite.com> suite!tarbell@uunet.uu.net writes: >Have you ever tried to get a DMM to measure its own battery voltage? > >It seems that one must decouple the input from the battery terminals, >but there must be a trick to it (I'm using a .01mfd disc cap). > Yes, one can manually simulate a kind of sample & hold circuit using a capacitor. Use a 1000 microfarad capacitor to sample the battery voltage of the DMM. Since DMM's usually have an internal resistance of about 1 to 10 MOhms, you should most likely be able to get a reading within +/- 1 least significant digit for a 3.5 digit DMM (1/2000 of full scale) off the charged capacitor for at least a duration of approximately 1MOhm*1000uF/2000= 500 ms (1/2000 of the time constant). This time is barely enough to observe a stable digital display, unless there is a bar display, or a hold-display function. One can even go further and design an electronic sample-and-hold circuit that has a periodic sampling interval. A simple one can be designed by using a pair of MOSFET SPDT bilateral switches ( If I am not mistaken, CD4069 would do it) to alternately connect the capacitor terminals to the battery poles and the measurement probes. The switching frequency can be increased in order to use a smaller holding capacitor. >What happens is that the display cycles +/- 2 volts around the true >value, but never settles down, seeming to indicate a ground loop. > >Any ideas? IMHO, the fluctuation in the display might be the side effect of a feedback mechanism built into the DMM circuitry to offset a common mode voltage appearing in the differential inputs of the DVM circuitry. Another possibility is that one of the probe terminals does not have a high series resistance in its connection to the DMM, and connecting it to a battery terminal causes considerable battery current to flow through this path, causing a drop in battery voltage, and therefore, a malfunction in circuitry sensitive to the supply voltage (a ground loop, using your terminology). A high current through a probe may also drive the input op-amp into saturation, with displayed results depending on the type of ADC and display control methods used. Yours, -- Mustafa KOCATURK mustafa@seas.smu.edu Electrical Engineering Department Home:(214)706-5954 Work:(214)692-2541 SMU Box 753190, Dallas, TX 75275-3190
Technical Details
Message-ID:
<1992Sep10.053134.19847@seas.smu.edu>Path:
arc1-ca.pugleaf.net!sparky!uunet!cs.utexas.edu!convex!seas.smu.edu!mustafaReferences:
<BuAB37.6I6@suite.com>Show Full Headers
Complete Article Headers
Newsgroups: sci.electronics Path: arc1-ca.pugleaf.net!sparky!uunet!cs.utexas.edu!convex!seas.smu.edu!mustafa From: mustafa@seas.smu.edu (Mustafa Kocaturk) Subject: Re: Try this with your DMM Message-ID: <1992Sep10.053134.19847@seas.smu.edu> Summary: Using a DMM to measure its own battery voltage Sender: news@seas.smu.edu (USENET News System) Nntp-Posting-Host: zebra.seas.smu.edu Organization: SMU School Of Engineering and Applied Science References: <BuAB37.6I6@suite.com> Date: Thu, 10 Sep 1992 05:31:34 GMT Lines: 46