mcovingt@athena.cs.uga.edu (Michael A. Covington) writes: > There's one BIG possible problem: The grounding is done differently. > > As I understand it, European 220V service is like American 120V service, > in that one side of the line is at ground potential. Right? > > American 220V service is different. Neither side of the line is grounded. > What you have is a 240-volt center-tapped transformer with the center > tap grounded. 120-volt service uses half of the transformer, with the > center tap as "neutral." 240-volt service uses both sides of the transformer > > It's overwhelmingly probable that the power supplies in your equipment > will expect "neutral" to be grounded, and will fry something if it isn't. > > The best way to deal with the Amstrad PC is to replace its power supply with > an American one, or look inside for a 120v-vs-220v jumper or switch (many > computers have them). Ditto the low-powered audio equipment. The huge > audio power amplifier will be more difficult; can you replace its > power transformer with one that has a 120v primary? > > > -- > + Michael Covington - Artificial Intelligence Programs - U of Georgia - USA > + Unless otherwise noted, these are private opinions, not official statements > + VOTE NO GEORGIA LOTTERY - we need not imitate mistakes of other states. I'll be surprised if your equipment depends on the line for a ground. US 120 volt 60 hz stuff doesn't. The frequency difference will affect stuff that has synchronous motors, or other things that take their frequency from the line. Trans- formers should do ok, since they will have more iron than a 60Hz one, and should benefit from the higher frequency. Good luck, and use the right size fuses. gerry@bluemoon.rn whose home bbs has trouble getting the mail out sometimes, so it may go here instead.
Technical Details
Message-ID:
<TiHFqB4w165w@bluemoon.rn.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!usc!sol.ctr.columbia.edu!zaphod.mps.ohio-state.edu!n8emr!bluemoon!gerryReferences:
<1992Aug30.183748.1399@athena.cs.uga.edu>Show Full Headers
Complete Article Headers
Newsgroups: sci.electronics Path: arc1-ca.pugleaf.net!sparky!uunet!usc!sol.ctr.columbia.edu!zaphod.mps.ohio-state.edu!n8emr!bluemoon!gerry From: gerry@bluemoon.rn.com (Gerard M. Foley) Subject: Re: Can 220V 50 Hz Stuff be run on US 220V 60 HZ power ? Message-ID: <TiHFqB4w165w@bluemoon.rn.com> Sender: bbs@bluemoon.rn.com (BBS Login) Organization: Blue Moon BBS ((614) 868-998[024]) References: <1992Aug30.183748.1399@athena.cs.uga.edu> Date: Tue, 01 Sep 92 11:14:28 EDT Lines: 37