🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: sci.electronics
Article #747

Re: How can I recognize true ground?

#747
From: Peter Fales
Date: Fri, 07 Jul 1989 22:47
43 lines
2112 bytes
In article <1989Jul7.155721.19105@utzoo.uucp>, henry@utzoo.uucp (Henry Spencer) writes:
> In article <18425@mimsy.UUCP> spector@brillig.umd.edu.UUCP () writes:
> >Question from a novice: My house has "two prong" outlets.  I've been told
> >that the center screw and casing of the outlet boxes is generally grounded,
> >so that I will have a correctly grounded outlet if I attach the wire of a
> >"3 to 2 adapter" to the center screw.  How do I (a vertual electronics
> >know-nothing) check to see if this is working in my case?
> 
> If you are really, seriously concerned about whether it really is grounded,
> you can't assume that the screw is grounded, and in fact you can't assume
> that the third prong in a three-prong outlet is grounded -- electricians
> do get sloppy now and then.
> 
> I'm unable to think of a quick no-equipment test to make sure; perhaps one
> of the higher gurus can.

If I understand what you are asking, any hardware store should have an
AC line tester.  This is not a "no equipment" test, but it doesn't cost
more than a couple of dollars, and 
is a small device about the size of a three prong
plug containing two green and one red neon bulbs.  When you plug it into
a three prong outlet (or your grounded 3-2 adapter), it will show 
several common wiring errors such as reversed hot/neutral, missing ground,
and a few others.  It is probably not 100%, but it gives you a better
feeling.  I found several outlets in my house with hot/neutral reversed.

i
n
e
w
s

f
i
l
l
e
r
-- 
Peter Fales			AT&T, Room 5B-420
				2000 N. Naperville Rd.
UUCP:	...att!ihlpb!psfales	Naperville, IL 60566
Domain: psfales@ihlpb.att.com	work:	(312) 979-8031
Technical Details
Message-ID: <1623@cbnewsc.ATT.COM>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!rutgers!tut.cis.ohio-state.edu!att!cbnewsc!psfales
References: <18425@mimsy.UUCP> <1989Jul7.155721.19105@utzoo.uucp>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!rutgers!tut.cis.ohio-state.edu!att!cbnewsc!psfales
From: psfales@cbnewsc.ATT.COM (Peter Fales)
Newsgroups: sci.electronics
Subject: Re: How can I recognize true ground?
Message-ID: <1623@cbnewsc.ATT.COM>
Date: 7 Jul 89 22:47:20 GMT
References: <18425@mimsy.UUCP> <1989Jul7.155721.19105@utzoo.uucp>
Organization: AT&T Bell Laboratories
Lines: 43