Article View: sci.electronics
Article #8307Zenith Motion Sensor:Latched On After Power Fail
From: Mark C.
Date: Mon, 12 Nov 1990 18:33
Date: Mon, 12 Nov 1990 18:33
15 lines
1127 bytes
1127 bytes
After installing a few Zenith motion sensor flood light's I
noticed that the power failures of just a few seconds seem to
fool the light into going into an "over ride mode" that is
designed for those who wire them to a switched outlet. This
mode makes the light stay on until reset (day or night!)
I've found the the removal of a diode from the circuit
disables this function an hence the problem in the "allways hot"
wiring configuration. Cut (or unsolder) D8 on the model SL-5410
--
####################
# #
# Mark C. #
# #
####################
Technical Details
Message-ID:
<1944.273ea4bb@iccgcc.decnet.ab.com>Path:
arc1-ca.pugleaf.net!utzoo!attcan!uunet!abvax!iccgcc!carneyShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!uunet!abvax!iccgcc!carney From: carney@iccgcc.decnet.ab.com (Mark C.) Newsgroups: sci.electronics Subject: Zenith Motion Sensor:Latched On After Power Fail Message-ID: <1944.273ea4bb@iccgcc.decnet.ab.com> Date: 12 Nov 90 18:33:47 GMT Lines: 15