Re: Simple RIAA phono filter

#8442
From: Dan Dunphy
Date: Fri, 16 Nov 1990 20:40
7 lines
783 bytes
Normally you only need an RIAA preamp/filter for a moving magnet
cartrige. This curve is required becauuse the MM cartiige is
a velocity device, in other words, the highest signal occurs
at the zero crossing of the groove wiggle. The output is
usually only a few millivolts.
A ceramic cartrige is an amplitude sensitive device, and
would require a different type of compensation if any.