Re: Electric motor connections

#8688
From: Greg Ebert
Date: Mon, 03 Dec 1990 16:59
44 lines
1936 bytes
In article <1990Dec2.220920.14435@cs.UAlberta.CA> steve@cs.UAlberta.CA (Steve Sutphen) writes:
> [...]
>
>4-------------------------------------- to field winding `A'
>
>V--------||---||-------->|
>                         |
>                         |
>2_________________H______|------------- to field winding `A'
>
>3-------------------------------------- to field winding `B'
>
>1-------------------------------------- to field winding `B'
>
I havn't worked with the exact motor you have, but I've tinkered with a
similar one. Hope this helps.

These guys look like a (from a circuit-sense) as :


AC line -----------*------ switch --| |-----
		   |                        |
                 Stator                   Start
		 Coil                     Coil
		   |                        |
		   |                        |
AC line -----------*-------------------------


The switch is closed when the RPM is low (~75% rated speed). The direction of
rotation is determined at power-on. If you disconnect the starter winding, you
can manually start a motor in either direction. Better yet, just switch the
'polarity' of the stator winding with respect to the start winding to reverse
the direction.

To get your motor to run:

	Connect terminal 2 to AC line.
	Connect terminal V to terminal 1
	Connect terminal 4 to AC neutral
	Connect terminal 1 to AC neutral

To reverse direction, interchange 1 and 3.
Technical Details
Message-ID: <1748@gold.gvg.tek.com>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!uunet!zephyr.ens.tek.com!gvgpsa!gold.gvg.tek.com!grege
References: <1990Dec2.220920.14435@cs.UAlberta.CA>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!uunet!zephyr.ens.tek.com!gvgpsa!gold.gvg.tek.com!grege
From: grege@gold.gvg.tek.com (Greg Ebert)
Newsgroups: sci.electronics,rec.woodworking
Subject: Re: Electric motor connections
Keywords: standard GE motor
Message-ID: <1748@gold.gvg.tek.com>
Date: 3 Dec 90 16:59:23 GMT
References: <1990Dec2.220920.14435@cs.UAlberta.CA>
Followup-To: sci.electronics
Organization: Grass Valley Group, Grass Valley, CA
Lines: 44