From: Bob Jewett
Date: Thu, 20 Jul 1989 02:55
19 lines
1062 bytes
> I have a 120v/12v transformer driving about 25 12v, 20
> watt halogen bulbs (I am not sure of the output current of the trans-
> former).
...
> Since this is for a pre-wired house, not a lot of rearranging of bulbs,
> wires, etc can be done.

12V and 20W implies about 2 amps per bulb, times 25 bulbs gives 50 amps.
Check your wires out.  If they are not rated for 50 amps, you are risking
starting a fire.

One solution that requires at least a little rewiring is to put 10 bulbs in
series rather than parallel.

> I appreciate any and all discussion about my problem...

What does the electrical code in your area permit?