Article View: sci.electronics
Article #8942Re: Can fuses get "worn out"?
From: Shailendra Anant Save
Date: Fri, 14 Dec 1990 19:11
Date: Fri, 14 Dec 1990 19:11
38 lines
2948 bytes
2948 bytes
In article <1990Dec14.171020.3615@phri.nyu.edu>, roy@alanine.phri.nyu.edu (Roy Smith) writes:
> replaced the motor, and yesterday, one of the 15A cartridge fuses protecting
> it blew. We replaced the fuse and the A/C came back on, but we're worried
> that there is more to it that just a chance fuse failure.
>
> The motor only draws about 6A (yes, I know about startup surges), so
> I think the fuses are the right size. My current theory is that when the
> previous motor died, it wasn't quite drawing enough current to blow the
> fuse, but "damaged" it enough that two weeks later a normal startup surge
> was enough to blow it completely. Is this possible? Do fuses act that way?
Yes, fuses act this way. A very untechinical explanation would be that the
repeated cooling and heating of the fuse would put enough stress on it that it would
just plain break. I don't know what would happen if you left the motor running
on continuously after it has been turned on, since then there would be no temp.
cycling. I do know that my car fuses blow quite often, usually when I am in
real bad weather. I haven't quite figured that out yet.
Some related thoughts. Many applicatons nowadays no longer use fuses for
engineered weak-points in the circuit. Most are now converting to circuit-breakers,
which are solid-state devices, reasonably cheap when doing a lot of experimental
work, where you are liable to blow a lot of fuses. These breakers do have reset
switches which can do the equivalent of replacing a blown fuse.
The other thing is that you said that you used a 15A fuse for taking startup
surges into account on a normal 6A load. A better alternative is to use a 6A
'slow-blow' fuse. Meaning that it takes a longer time to melt and hence not
blow during start-ups. I have found that to be safer.
--Shailendra
--
Physical: Shailendra Save, Logical: ssave@caen.engin.umich.edu
2303 Conger Baits II, UUCP: ...!umix!caen.engin.umich.edu!ssave
Ann Arbor. MI 48109. Audible: 313-763-1627(H) 313-764-8033(O)
ICBM: 42 33'W 83 71'N Fax: 313-747-1781
Eagles may soar, but weasels don't get sucked into jet engines.
(For those who don't know, a weasel is a wolverine)
Technical Details
Message-ID:
<1990Dec14.191104.28628@engin.umich.edu>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!zaphod.mps.ohio-state.edu!caen!jameson.engin.umich.edu!ssaveReferences:
<1990Dec14.171020.3615@phri.nyu.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!zaphod.mps.ohio-state.edu!caen!jameson.engin.umich.edu!ssave From: ssave@caen.engin.umich.edu (Shailendra Anant Save) Newsgroups: sci.electronics Subject: Re: Can fuses get "worn out"? Summary: Variable blow fuses. Message-ID: <1990Dec14.191104.28628@engin.umich.edu> Date: 14 Dec 90 19:11:04 GMT References: <1990Dec14.171020.3615@phri.nyu.edu> Sender: news@engin.umich.edu (CAEN Netnews) Organization: The University of Michigan, Ann Arbor Lines: 38