🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: sci.electronics
Article #9458

Re: YMHWQ (Yet more house-wiring questions)

#9458
From: Rob Fugina
Date: Fri, 11 Jan 1991 18:08
18 lines
1693 bytes
In article <1864@gold.gvg.tek.com> grege@gold.gvg.tek.com (Greg Ebert) writes:
>While on the subject of house wiring and kWh meters, my former residence
>had 2 legs of a 208 3-phase system for wiring (I verified w/ scope). I
>just realized that my kWh meter probably UNDER-read my actual energy
>consumption because for a line-to-neutral resistive load, the current
>and voltage peaks are 30 degrees out-of-phase with eachother. For 
>line-to-line resistive loads, the voltage and current are in-phase, thus
>it would read correctly. Anyone concur ? 

I don't know how kWh meters work, so I can't tell you anything about how
it would measure your power consumption, but I can tell you this.  As far
as line-to-neutral lines in your house are concerned, they would all
work correctly...BUT, anything that you have connected line-to-line, like
an electric furnace, water heater, or stove/oven, they're not getting
the 220v RMS that they're supposed to get...they're only getting
1.73 * 110 instead of 2 * 110.  They're getting 190.5v RMS.

Rob  robf@cs.umr.edu
Technical Details
Message-ID: <1921@umriscc.isc.umr.edu>
Path: arc1-ca.pugleaf.net!utzoo!censor!geac!torsqnt!lethe!yunexus!ists!helios.physics.utoronto.ca!news-server.csri.toronto.edu!bonnie.concordia.ca!thunder.mcrcim.mcgill.edu!snorkelwacker.mit.edu!apple!usc!samsung!uakari.primate.wisc.edu!umriscc!mcs213j.cs.umr.edu!robf
References: <1864@gold.gvg.tek.com>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!censor!geac!torsqnt!lethe!yunexus!ists!helios.physics.utoronto.ca!news-server.csri.toronto.edu!bonnie.concordia.ca!thunder.mcrcim.mcgill.edu!snorkelwacker.mit.edu!apple!usc!samsung!uakari.primate.wisc.edu!umriscc!mcs213j.cs.umr.edu!robf
From: robf@mcs213j.cs.umr.edu (Rob Fugina)
Newsgroups: sci.electronics
Subject: Re: YMHWQ (Yet more house-wiring questions)
Keywords: wiring, electric meter, KWH
Message-ID: <1921@umriscc.isc.umr.edu>
Date: 11 Jan 91 18:08:41 GMT
References: <1864@gold.gvg.tek.com>
Sender: news@umriscc.isc.umr.edu
Organization: University of Missouri - Rolla
Lines: 18