Article View: sci.electronics
Article #9476Simpson 260-8 Mods
From: Ken Gianino 5-9081
Date: Fri, 11 Jan 1991 16:53
Date: Fri, 11 Jan 1991 16:53
13 lines
944 bytes
944 bytes
If you have a new Simpson 260-8 VOM it is very easy to add the audible continuity tester that is included on the 260-8P. All of the wiring is there already, you just need to solder a piezo-buzzer to the circuit board. A Radio Shack 273-074 fits perfectly. Take the back housing off and solder the buzzer in the two extra holes on the right side of the pc board. Positive should be oriented towards the bottom of the meter case. To use the audible contiuity funtion, turn the meter switch to OFF. When you touch the probes together it will beep without any meter indication. -Ken
Technical Details
Message-ID:
<1991Jan11.165323.2564@swbatl.sbc.com>Path:
arc1-ca.pugleaf.net!utzoo!censor!geac!torsqnt!news-server.csri.toronto.edu!cs.utexas.edu!wuarchive!swbatl!kenShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!censor!geac!torsqnt!news-server.csri.toronto.edu!cs.utexas.edu!wuarchive!swbatl!ken From: ken@swbatl.sbc.com (Ken Gianino 5-9081) Newsgroups: sci.electronics Subject: Simpson 260-8 Mods Message-ID: <1991Jan11.165323.2564@swbatl.sbc.com> Date: 11 Jan 91 16:53:23 GMT Organization: Southwestern Bell Lines: 13