Article View: sci.electronics
Article #9549Re: ANOTHER house wiring question (this one's basic)
From: J. Deters
Date: Wed, 16 Jan 1991 19:24
Date: Wed, 16 Jan 1991 19:24
45 lines
2582 bytes
2582 bytes
[ Uh oh, here we go again! It's my turn, guys, I saw it first! ]
DANGER, WILL ROBINSON, DANGER.
This idea seems to make it around sci.electronics at least once a year
or so.
+------------------------+
>>>>>>>>>>>>>>>>>>>>>> | NEUTRAL IS NOT GROUND! | <<<<<<<<<<<<<<<<<<<<<<
+------------------------+
> Article <1948@umriscc.isc.umr.edu> From: robf@mcs213k.cs.umr.edu (Rob Fugina)
>In article <kJhTxoE@quack.sac.ca.us> mrapple@quack.sac.ca.us (Nick Sayer) writes:
>>Now ground and neutral clearly are not the same thing. I would
>>expect negative side effects were I foolish enough to hook
>>a light bulb between hot and ground.
[It will work, but you don't want to run it this way]
>Ground and neutral are exactly the same thing. If you were to trace the
>wires back to your breaker box, you would find bare wires (ground) and white
>wires (neutral) both connected to a grounding strip.
Neutral exists as a return path for the current. It is an active part
of the current flow. Ground, on the other hand, is there for safety.
You should never (NEVER) use ground as a designated return path for the
current. Ground exists (for among many other reasons) so that if a
device's insulation fails, there is a safe path for current to return
so that the fuse or circuit breaker can trip. You wouldn't want that
return path to be you...
>MY QUESTION is, if you don't have 3-wire connections in your house, why
>can't you connect the white wire to the ground lug and conuit/boxes, etc???
Have you ever disconnected a piece of conduit that was acting as neutral,
or even touched one while standing on a wet concrete floor? It's unpleasant,
to say the least, and it surprises the hell out of you!
-j
--
J. Deters
INTERNET: jad@dayton.DHDSC.MN.ORG We've changed our location, and
UUCP: ...!bungia!dayton!jad we are now in our new lab. Please
ICBM: 44^58'36"N by 93^16'14"W <-- update your target list accordingly.
Technical Details
Message-ID:
<7645@dayton.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!sdd.hp.com!zaphod.mps.ohio-state.edu!rpi!uwm.edu!src.honeywell.com!msi.umn.edu!cs.umn.edu!kksys!com50!dayton!jadReferences:
<kJhTxoE@quack.sac.ca.us> <1948@umriscc.isc.umr.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!sdd.hp.com!zaphod.mps.ohio-state.edu!rpi!uwm.edu!src.honeywell.com!msi.umn.edu!cs.umn.edu!kksys!com50!dayton!jad From: jad@dayton.UUCP (J. Deters) Newsgroups: sci.electronics Subject: Re: ANOTHER house wiring question (this one's basic) Keywords: DANGER! Message-ID: <7645@dayton.UUCP> Date: 16 Jan 91 19:24:38 GMT References: <kJhTxoE@quack.sac.ca.us> <1948@umriscc.isc.umr.edu> Reply-To: jad@dayton.DHDSC.MN.ORG (J. Deters) Organization: Department Store Division of DHC Lines: 45