Duke McMullan responded with a neat little bootstrap transformer circuit, and
eventually warned us:
. . . Wire appropriately; don't exceed the current
rating of the secondary (primary current won't be a problem).
Only a small quibble: the *primary* current is what you have to worry about,
not the secondary: since all the load current flows through both transformer
windings, they get equal current, unlike the usual case where the primary is
low current and the (step-down) secondary is much higher. You'd want to first
find out what the primary current rating *is* before selecting the transformer
to use. To wit:
Power_rating = sec._voltage (24) * sec._current_rating (e.g. 3A) = 72 Watts
Primary_current_rating = Power_rating / 120VAC, or 0.6 A in this example.
If the equipment you want to power doesn't give a current draw, calculate it
from the power spec: Equipment_power / 100 VAC = Equipment_current, which
must be significantly less than the transformer's primary current rating...
Good luck! Dave dbell@cup.portal.com
Technical Details
Message-ID:
<25539@cup.portal.com>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!wuarchive!uunet!portal!cup.portal.com!dbellReferences:
<3215@uceng.UC.EDU> <1201@ariel.unm.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!wuarchive!uunet!portal!cup.portal.com!dbell From: dbell@cup.portal.com (David J Bell) Newsgroups: sci.electronics Subject: Re: 100V Japanese products on 120V US lines Message-ID: <25539@cup.portal.com> Date: 1 Jan 90 07:06:29 GMT References: <3215@uceng.UC.EDU> <1201@ariel.unm.edu> Distribution: na Organization: The Portal System (TM) Lines: 21