>     The answer is THEY must go between VCC and GROUND on the SAME
>     chip.  The reason for a despiking cap is the momentary
>     current rush caused by switching in DRAMs and some other
>     chips.  The cap supplies the current needing for these chips
>     and prevents them from degrading the powersupply.  By
>     placeing them not Immediatly to the chips ground you are
>     totally defeating thier purpose.
> 

No, they do NOT need to go on the same IC if that means longer cap leads
than simply tying to the nearest ground point.  Assuming a board with
power/ground planes, or a power/ground "grid" as Henry mentioned (easily
"do-able" on a wire-wrap board, this may mean that the caps tie to power and
ground *between* adjacent ICs.  Distributing the capacitance across the
power plane is the key, not tying the caps to a given chip.


Bob Myers  KC0EW   Hewlett-Packard Co.      |Opinions expressed here are not
                   User Interface Tech. Div.|those of my employer or any other
myers@fc.hp.com    Fort Collins, Colorado   |sentient life-form on this planet.
Technical Details
Message-ID: <7480126@hpfcso.FC.HP.COM>
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!sdd.hp.com!scd.hp.com!hplextra!hpfcso!myers
References: <jeremym.718096983@sfu.ca>

Show Full Headers
Complete Article Headers
From: myers@hpfcso.FC.HP.COM (Bob Myers)
Date: Thu, 8 Oct 1992 17:06:05 GMT
Subject: Re: Can despiking caps be connected to a central ground?
Message-ID: <7480126@hpfcso.FC.HP.COM>
Organization: Hewlett-Packard, Fort Collins, CO, USA
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!sdd.hp.com!scd.hp.com!hplextra!hpfcso!myers
Newsgroups: sci.electronics
References: <jeremym.718096983@sfu.ca>
Lines: 20