In article <1k68g7INN2ei@gap.caltech.edu> carl@SOL1.GPS.CALTECH.EDU writes: >In article <C1IpIq.DFF@usenet.ucs.indiana.edu>, amirza@bronze.ucs.indiana.edu (Anmar Caves) writes: >>>If you use a 12 volt system you can start out with one set of batteries >=>and add capacity in parallel. If you are on 120 volts dc you have 10 >=>times the number of cells. The initial cost for a 120 volt system will be >=>much higher. >= >=In addition, there will be ten times the number of cells in series. > >But the same total number of cells in your storage system. Yep. But, you can get away with mixing different aged banks in parallel. It's not the best for a system, but it isn't too detrimental. Replacing one cell in a series system *can* be detrimental and can lead to reverse charging and increased sulfation if lead acid cells. It's best that all cells in a series system be the same type, capacity and age. It's not absolutley ruinous to replace one cell (or one battery if using 6 or 12volt batteries to make up the 120 volt battery, hmm, a battery of batteries?) in a 120volt battery, but it is more so than replacing once battery in a 10 12volt battery system. >=Any one cell failure can ruin a bank. > >The same is true if the cells are connected in parallel: One shorted cell can >load the rest enough to damage them. I wasn't talking about a shorted cell. In a bank of 60 cells connected in series a shorted cell would hardly be noticed. The charge/discharge voltage fluctuation is much higher than that (like around 10 volts). In a bank of 60 series-parallel cells working at 12 volts it could blow up the cell (more likely it wouldn't happen because most shorts would get burned away before they became serious). But shorted cells in a lead acid bank for that type of application rarely happen unless you drop your wrench on them (shame on you! why didn't you insulate all exposed leads!). On that I speak from experience. With lead acid banks in stand by or home use configuration the most common failure mode is sulfation. I generally try to avoid this by dropping the acid content on the cells to about 1.2 sp. grav. fully charged. -- Anmar Mirza # Chief of Tranquility #My Opinions! NotIU's!#Purveyor of EMT-D # Base, Lawrence Co. IN # Legalize Explosives!#nontraditional N9ISY (tech) # Somewhere out on the # Politicians prefer #family values Networks Tech.# Mirza Ranch.C'mon over# unarmed peasants. #Space For Rent
Technical Details
Message-ID:
<C1J2w7.Iu0@usenet.ucs.indiana.edu>Path:
arc1-ca.pugleaf.net!sparky!uunet!crdgw1!rpi!usc!sdd.hp.com!ux1.cso.uiuc.edu!usenet.ucs.indiana.edu!bronze.ucs.indiana.edu!amirzaReferences:
<1993Jan23.061702.18014@mnemosyne.cs.du.edu> <C1IpIq.DFF@usenet.ucs.indiana.edu> <1k68g7INN2ei@gap.caltech.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!crdgw1!rpi!usc!sdd.hp.com!ux1.cso.uiuc.edu!usenet.ucs.indiana.edu!bronze.ucs.indiana.edu!amirza From: amirza@bronze.ucs.indiana.edu (Anmar Caves) Newsgroups: sci.energy Subject: Re: Why not 120 VDC ? Why invert? Message-ID: <C1J2w7.Iu0@usenet.ucs.indiana.edu> Date: 27 Jan 93 19:45:43 GMT References: <1993Jan23.061702.18014@mnemosyne.cs.du.edu> <C1IpIq.DFF@usenet.ucs.indiana.edu> <1k68g7INN2ei@gap.caltech.edu> Sender: news@usenet.ucs.indiana.edu (USENET News System) Organization: Indiana University Lines: 47 Nntp-Posting-Host: bronze.ucs.indiana.edu