Article View: sci.energy
Article #2353Sample solar problems
From: William R Stewart
Date: Fri, 17 May 1996 00:00
Date: Fri, 17 May 1996 00:00
289 lines
11932 bytes
11932 bytes
Nick Pine wrote: > > William R Stewart <wstewart@patriot.net> wrote: > >Nick Pine wrote: > > >>Here's another litmus test for an energy expert: what will the average water > >>temperature be inside a 4' cube full of water surrounded by 5 R20 foam walls, > >>sitting outside in December, when the air has an average 24 hour temperature > >>of 36 F and the sun puts 1,000 Btu/ft^2/day of heat into the R1 glazed side > >>of the box? And how will that change over time if we shade the sunny wall? > >>Anyone care to answer that question? I'll offer a $10 reward to the first > >>person who answers it correctly. > >You don't give enough data in order to answer your question, and your question > >is not clearly stated.\ > >The water in the cube would rise to a steady state temperature of > >36 +80 = 116 oF if the energy input were continuous. > > Perhaps, but recall the problem: > > >>the sun puts 1,000 Btu/ft^2/day of heat into the R1 glazed side of the box. > >>And how will that change over time if we shade the sunny wall? > >When shaded, the water in the cube would fall over time to 36oF. I showed how it would change over time. You owe me ten bucks, Nick :-) > >A complete answer with specific times would require calculus, if specific > >times was what you were looking for. Otherwise, simple arithmetic would give the wrong answer, as this is obviously not a linear relationship. > Yes, that was what I was looking for. More than the obvious... Finding the > form of the answer requires calculus, but Newton did that once, a long long > time ago. Finding the answer just requires plugging some numbers into a > simple formula, if you know the formula. Present the formula and we will see if it produces the correct answer, or even a very close answer. > >4000 lbs of water would require 2.5 hours of 1600 btu/hr energy input, again > >without considering the loss through the cube walls. So here is an answer with a specific time; what's your beef? > True, but why are you talking about heating rather than cooling? Because you asked for it!!! > Sorry. No $10. Would you like to try again? Welcher! > * * * > > At this point, Mr Stewart changes the subject: > > >Now, if you; > > -moved the water inside to the interior sunspace of a 68oF house, > > -made the glazing 7'x10 (4 in the entire house on the south side) > > ie 280 ft^2 of south glazing? > > > -used a flatter 4"x4'x10' water wall (4 in the entire house), 4" away > > from the glazing inside the house, > > ie about 400 pounds of water? 4" away from the glazing? Transparent > water? Hmmm :-) I guess you won't be able to see very clearly out of > those windows, but they will let in some light... > > > -used an R4 glazing when the sun was shining, > > With how much solar transmittance, at what cost, and what happens when the > argon leaks out?Some of these $40/ft^2 high-R windows have low solar > transmittance, on the order of 50%. Hmmm, 280 ft^2 x $40/ft^2 = $11,200. You must be thinking of R8 windows; Where do you get your figures? I'm not going with low-E due to insolation losses. > > and an extra R8 window cover when the sun wasn't shining, > > How would you do that? Movable insulation, at $10/ft^2, installed? Again, where do you get your prices? >Will you move it twice a day religiously? Just like you close your windows when it gets to cool at night. >Will it leak any air around the edges? Probably, but certainly much less than an outdoor thin film sunspace. > >then you would have a direct, passive solar design that retained the sun's > >heat energy in the building interior and released it slowly into the > >interior at night > > Right. Another "direct loss" house :-) Er, do you have a house that does not lose heat when it is cold outside? > >Care to try the math? > > Sure. I like this arithmetic. Let me get a cup of coffee... Now I'm back, > 200 Btu later. I've had this espresso machine for about 3 months now. I > guess if some people like me find it fun to wiggle the valves on an espresso > machine with all the steam and noise and watch the milk temp rise with a > thermometer twice a day, others might find it fun to move window insulation > all over a house twice a day, for three months... Or, maybe you only move > the window insulation on a cloudy winter day--but no, you want to do it at > night too... or you might leave some windows covered all winter, like Pat > Hennin or Malcolm Wells, in semi-hibernation, huddled in cold dark rooms. > > >assume another 60 ft^2 of window at R4 during the day, adding > > another R8 at the other 14 hours. > > OK. That's a long winter day... You forgot to add R8, you only added R4 > >Assume R24 walls and R38 ceiling. > > OK. Let's assume that includes the 2x6's, etc, that act as thermal shunts, > ie the equivalent thermal resistance of the entire wall is R24. This is not > just a wall with layers of insulation with R-values that add up to R24 > (which might have a much lower R-value), and the insulation is installed > properly with no gaps, etc. Are you sure about all that? Another inch of polyisocyanurate, and various other siding and finishing materials. > >Assume a two story, 24'x 48' floorspace house with 8' ceilings. > > OK. I guess you mean the footprint on the ground is 24 x 48? Right. > So the house volume is 24 x 48 x 16 = 18432 ft^3. > >Assume an outside temperature of 36 oF > > OK. (The average will be warmer during daylight, which is good.) > > >Assume 0.25 air changes per hour (optional). > > OK. That's 0.25 x 18432 ft^3/hr = 4608 ft^3/hr or 77 cfm :-) I'll assume > (I almost said "guess") this is leakage thru walls, etc, without an air-air > heat exchanger... Will the finished house have a blower door testing spec? Yes, and the top limit will be 0.25 air changes; I expect alot less. > May we also assume you use a frugal 500 kWh/month of electricity, ie an > average of about 700 Watts? Why does this matter? I will be using a 2kW photovoltaic system. > (Steve Baer only uses 80 kWh/mo :-) How much do you use, coffee and all? > This is > equivalent to 700 x 3.41 = 2387 Btu/hr. Let's add the heat from two > 300 Btu/hr people inside the house for 16 hours a day, and one 150 Btu/hr > dog and a 50 Btu/hour cat, full-time. Total internal energy generation: > 2387(24)+600(16)+200(24) = 72K/day. > > >Assume 100 Btu/hr/ft^2 insolation over 10 hours every day. > > OK. > > >Make an assumption about the thermal storage of the rest of the interior > >items/material. > > How about 1 lb of water/ft^2 of walls and ceiling? (1/2" drywall has the > equivalent of 1/2 lb of water/ft^2, so you may need some concrete furniture..) > I'll make some other assumptions, too. OK > I guess we'd want to know the thermal resistance of this house for starters. > So let's add up the thermal conductances U = Sum(Ai/Ri) and find > the reciprocal 1/U... > > We have 340 ft^2 of windows, 4 sets of 10' x 7' windows = 2800 ft^2 >R4 during a 10 hour day (Uday = 340/4 = 85) > and R8 during a 14 hour night R12 at night; R4 + R8 (Unight = 340/8 = 43), with an average daily > Uwindow = (10xUday+14xUnight)/24 = 60. > > Uwalls = (2(24+48)x16-340)/R24 = 82, and Uceiling = 24x48/R38 = 30. > > And Uinf = 77 Btu/hr-F. > > So U = 60+30+77 = 167 Btu/hr-F and R = 0.006, over 24 hours. These numbers have to be revisited. > At night the U value would be lower, after you devotedly travel around > the house and painstakingly put up your night insulation on every window, > making sure the edges are ever so carefully sealed, akin to some little > twice-daily religious experience... Unight = 43+30+77 = 150 Btu/hr-F. > > What will the steady state energy flow be for this house after a long > string of average December days, with an average amount of sun? > > The energy Ein that flows into this house in a day might be > > 280 ft^2 windows That should be 2800 ft^2 x 50% transmission Try 75% x 1000 Btu/ft^2/day = 140K > + internal energy generation = 72K > total Ein = 212K. > And the energy Eout that flows out of the house might be > > 24 hours x (68-36) x 167 = 128 K Btu/day. Of course, these numbers must be revisited as well. > Now, thermal mass: the house has about 3500 ft^2 of walls and ceilings with > a thermal mass equivalent to 3,500 pounds of water and another 400 pounds > of actual water. 10' x 4' x 4" is ~13 ft^3. Water is 62.4 lbs/ft^3. There are four water walls. The water will weigh close to 3250 lbs. > Let's call this 4,000 Btu/hr-F. You need to revisit this number as well. > So if you make the temp of > the house, say, 80 F at dusk, at the end of an average day, with some sun, > after a long string of December days, each with 1000 Btu/ft^2/day of sun, > during the night the house will lose approximately 14 hours (80-36) 150 = > 100K Btu, which might come from the 4,000 Btu/F of thermal mass cooling plus > 14/24 hours x 72K = 42K of internal energy generation, ie the temperature of > the house might drop to 80 - (100K-42K)/4K = 65 F at dawn. You have so many corrections to make before you hit this paragraph that I am reluctant to mention the ones within. You have not yet tried to establish the temperature of the water in the water walls. Your assumption seems to be 1 oF, though there is no evidence of how you tried to calculate this. > How much backup heat will you need in an average year? My wife wants a fireplace, so I will likely go with a masonry firestove, often referred to as a Finnish or Russian fireplace, with outside combustion air. > Were you planning to have hot water in this house? How were you planning > to do that? Solar hot water, most likely active. > A better way to compare heating systems > might be their yearly heating bills, including the electrical power to run > the heating system. The model I am planning on building (2250 ft^2) required $168 worth of heat for an entire winter. Reference "Solar Today", Sept/Oct 1995, article on manufactured house. > >Some people prefer the passive method, and it is not your perogative > >to tell them that they are wrong in preferring that. > > Oh sure it is, and it seems kind to tell people, if their passive houses are > such miserable and expensive performers. Try the numbers again, then we'll talk. Cheers, Will Stewart
Technical Details
Message-ID:
<319C008D.4D44@patriot.net>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<31919236.39F7@xs4all.nl> <3199C082.5A4A@patriot.net> <4nd2ko$8sb@vu-vlsi.ee.vill.edu> <319AAF35.40B4@patriot.net> <4nfed6$f9j@vu-vlsi.ee.vill.edu>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 10acd6,f1c9c9565efd24d X-Google-Attributes: gid10acd6,public X-Google-Thread: 107e5d,f1c9c9565efd24d X-Google-Attributes: gid107e5d,public X-Google-Thread: 10e415,9e29e85af0a4d9c2 X-Google-Attributes: gid10e415,public X-Google-Thread: fb752,f1c9c9565efd24d X-Google-Attributes: gidfb752,public X-Google-Thread: 1025ed,f1c9c9565efd24d X-Google-Attributes: gid1025ed,public X-Google-Thread: 10eede,2d054967bdd90e8 X-Google-Attributes: gid10eede,public From: William R Stewart <wstewart@patriot.net> Subject: Sample solar problems Date: 1996/05/17 Message-ID: <319C008D.4D44@patriot.net> X-Deja-AN: 155271336 references: <31919236.39F7@xs4all.nl> <3199C082.5A4A@patriot.net> <4nd2ko$8sb@vu-vlsi.ee.vill.edu> <319AAF35.40B4@patriot.net> <4nfed6$f9j@vu-vlsi.ee.vill.edu> followup-to: alt.energy.renewable,alt.solar.thermal content-type: text/plain; charset=us-ascii organization: PatriotNet, (703) 277-7737 mime-version: 1.0 newsgroups: sci.energy,alt.solar.thermal,alt.energy.renewable,alt.architecture.alternative,bit.listserv.geodesic,sci.engr.heat-vent-ac x-mailer: Mozilla 2.01KIT (Win95; U)