Article View: sci.engr.chem
Article #166Nitrate removal with the Flow Through Capacitor
From: Marc Andelman
Date: Fri, 16 Jan 1998 00:00
Date: Fri, 16 Jan 1998 00:00
63 lines
3240 bytes
3240 bytes
The following is posted here to put it more thoroughly into
into the public domain. This is work done on 10/2/96, and
has been already shared non cofidentially.
Nitrate removal with the FLow Through Capacitor.
Nitrate removal is an excellent application of
Flow Through Capacitors (FTC's). FTC's are described
in US patents 5,620,597 ; 5,415,768; 5,384,685; 5,360,540;
5,200,068; 5,196,115; 5,192,432;etc. to Marc Andelman,
and 5,538,611 to Toshiro Otowa, assigned to Marc Andelman
Ammonium Nitrate 10/2/96
capacitor, ten inch long, 2.5 inch diameter spiral wound activated
carbon cloth
amount of carbon 100 grams
Feed. 1.925 milliSiemen Ammonium Nitrate in 75 microSiemen
Worcester Tap Water
pH 6.54
Flow rate 130 ml/minute voltage, brought up to 2 volts over three
minute period.
Amperage settled out at around 8 amps.
Time
in milli-
minutes Siemens Volts ml/min pH
0 1.926 0 130 6.54
1 1.562 .5 130
2 .382 1 130
3 .168 2 130
4 .148 2 130
5 .157 2 130
6 .185 2 130
7 .338 2 130 8
8 .458 2 130
9-15 short 0
16 6.8 short 84 6.9
17 7.34 short 84
18 6.1 short 84 6.77
19 4.65 short 84
20 3.71 short 84
Results, FTC removed nitrate from an initial level of 1.925
milliSiemens,
to a low of .148 at the four minute point . This represents over 90%
removal.The activated cloth electrodes used here are an older design.
Capcitors made from the newer electrodes manufactured from thermally
activated
powdered carbon, formed into sheet electrodes, have about three times as
much volumtric surface area, and will certainly give even better
results.
1 Parkton Ave., Worcester, MA 01605 * Tel:(508) 853-8803 * Fax:(508)
853-8772
*E-mail *drgonfly@biosource.ultranet.com*
Technical Details
Message-ID:
<34C02C2B.50D7@ultranet.com>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailShow Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 10ecc0,2bcadf08e923c512,start X-Google-Attributes: gid10ecc0,public X-Google-Thread: f9b67,2bcadf08e923c512,start X-Google-Attributes: gidf9b67,public X-Google-Thread: 10b271,2bcadf08e923c512,start X-Google-Attributes: gid10b271,public X-Google-Thread: 12d4d1,2bcadf08e923c512,start X-Google-Attributes: gid12d4d1,public X-Google-Thread: 10df74,2bcadf08e923c512,start X-Google-Attributes: gid10df74,public X-Google-Thread: 10a119,2bcadf08e923c512,start X-Google-Attributes: gid10a119,public X-Google-Thread: fb19c,2bcadf08e923c512,start X-Google-Attributes: gidfb19c,public From: Marc Andelman <drgonfly@ultranet.com> Subject: Nitrate removal with the Flow Through Capacitor Date: 1998/01/16 Message-ID: <34C02C2B.50D7@ultranet.com> X-Deja-AN: 316737811 Content-Transfer-Encoding: 7bit X-Ultra-Time: 17 Jan 1998 03:59:15 GMT Content-Type: text/plain; charset=us-ascii X-Complaints-To: abuse@ultra.net Organization: Biosource Mime-Version: 1.0 Newsgroups: sci.engr.chem,sci.environment.waste,sci.engr.mining,sci.industry.pulp-and-paper,sci.physics,sci.chem.electrochem,ca.environment