Article View: sci.engr.micromachining
Article #5Re: <<< Optical alignment problem >>>
From: William Kaukler
Date: Sun, 10 Jan 1999 00:00
Date: Sun, 10 Jan 1999 00:00
29 lines
2068 bytes
2068 bytes
polymer cures always with a volume change. rate depends on temperature as much as initiator (UV). non-uniform temperature causes un uniform cure rate. this not based on experience with the adhesive in question as it was not specified. Yachin Yarchi wrote in message <36989446.BB35FBA1@newmail.net>... >I'm trying to join together two parts which make an optical device. >the part is a 1 mm dia. glass tube 16 mm long which seat in a holder 8 >mm long with a 2 mm dia. hole made of alodined aluminum. >I adjust the tube in the correct position with true position accuracy of > >1 micrometer (after applying UV adhesive to it). >when I expose the part to UV concentrated light source for few seconds, >I find that the tube tip had moved about 40 microns around the prior >positions. >I thought that it might be that the C=C double linkage which opens to >-C- linkage not uniformly, cause change in molecular volume and push the > >tube during curing. >If anyone is familiar with problems like that and can help me or refer >me to someone which may help me ,please do so. > >Thanks > >Yachin Yarchi > > >
Technical Details
Message-ID:
<Ck6jGvQP#GA.202@newstoo.hiwaay.net>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<36989446.BB35FBA1@newmail.net>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 1141dc,5375756b1a2e202c X-Google-Attributes: gid1141dc,public X-Google-Thread: 111a00,5375756b1a2e202c X-Google-Attributes: gid111a00,public X-Google-Thread: ff212,5375756b1a2e202c X-Google-Attributes: gidff212,public X-Google-Thread: 10c5ca,5375756b1a2e202c X-Google-Attributes: gid10c5ca,public X-Google-Thread: 104419,5375756b1a2e202c X-Google-Attributes: gid104419,public X-Google-Thread: f653f,5375756b1a2e202c X-Google-Attributes: gidf653f,public From: "William Kaukler" <kauklwf@airnet.net> Subject: Re: <<< Optical alignment problem >>> Date: 1999/01/10 Message-ID: <Ck6jGvQP#GA.202@newstoo.hiwaay.net> X-Deja-AN: 431099180 References: <36989446.BB35FBA1@newmail.net> Newsgroups: sci.engr.micromachining,sci.engr.metallurgy,fj.engr.misc,sci.materials,fj.engr.materials,sci.engr.manufacturing X-MimeOLE: Produced By Microsoft MimeOLE V4.72.3110.3