triple hot wire calibration

#2
From: George B. Ross
Date: Tue, 03 Nov 1992 14:13
44 lines
2443 bytes
  I am interested in hearing from anyone that is using look-up tables
for the calibration of cross hot wires and/or cross hot wires with
a third wire for temperature measurements.  I have read the papers
of Meyer and Lueptow et al that follow

Meyer, L., (1992) "Calibration of a Three-Wire Probe for Measurements 
in Nonisothermal Flow", Experimental Thermal and Fluid Science,
vol 5, no 3, pp 260-267.

Lueptow, R.M., Breuer, K.S., and Haritonidis, J.H., (1988) 
"Computer-aided calibration of X-probes using a look-up table"
Experiments in Fluids, vol 6, pp 115-118.

I have also looked in
1) IMSL libraries for multidimensional spline interpolation
2) Numerical Recipes and the several references that Numerical
   Recipes gives for multidimensional spline interpolation.

I am measuring the nonisothermal wake of a flat plate which is
thermally stratified for velocities in the 5-10m/s range.
Lueptow et al give a very good method for a X-wire calibration
via a look-up table, which I can recommend for use.  Meyer
states that to extend the method of Lueptow et al to a third 
dimension is a trivial matter (ha, I say).
I would use the method of Meyer, but it is less accurate at low
velocities.  Meyer basically uses the method of Lueptow et al
with a linear approximation for the temperature probe calibration,
which I don't understand why if the method of Lueptow et al is
easily extended to 3-d.  It can't be that computationally 
expensive, can it?

Now my questions:
1) Does anyone else do this sort of calibration?
2) Does anyone have a method or reference for 3-d look-up tables that
   they can recommend?

Any help you can give is greatly appreciated.  Please respond
via e-mail and I can redistribute if others are interested in 
this same information.

-george
=================  NeXTMail more than welcome  ==================
 George B. Ross          Heavens, I don't like the looks of that
 gross@stimpy.ame.nd.edu           Stimpson J. Cat 
Technical Details
Message-ID: <1992Nov3.141310.27495@news.nd.edu>
Path: arc1-ca.pugleaf.net!sparky!uunet!caen!spool.mu.edu!news.nd.edu!news

Show Full Headers
Complete Article Headers
Newsgroups: sci.geo.fluids
Path: arc1-ca.pugleaf.net!sparky!uunet!caen!spool.mu.edu!news.nd.edu!news
From: gross@stimpy.ame.nd.edu (George B. Ross)
Subject: triple hot wire calibration
Message-ID: <1992Nov3.141310.27495@news.nd.edu>
Keywords: hot wire, calibration, look-up tables
Sender: news@news.nd.edu (USENET News System)
Reply-To: gross@stimpy.ame.nd.edu
Organization: University of Notre Dame
Date: Tue, 3 Nov 1992 14:13:10 GMT
Lines: 44