Article View: sci.geo.fluids
Article #2triple hot wire calibration
From: George B. Ross
Date: Tue, 03 Nov 1992 14:13
Date: Tue, 03 Nov 1992 14:13
44 lines
2443 bytes
2443 bytes
I am interested in hearing from anyone that is using look-up tables for the calibration of cross hot wires and/or cross hot wires with a third wire for temperature measurements. I have read the papers of Meyer and Lueptow et al that follow Meyer, L., (1992) "Calibration of a Three-Wire Probe for Measurements in Nonisothermal Flow", Experimental Thermal and Fluid Science, vol 5, no 3, pp 260-267. Lueptow, R.M., Breuer, K.S., and Haritonidis, J.H., (1988) "Computer-aided calibration of X-probes using a look-up table" Experiments in Fluids, vol 6, pp 115-118. I have also looked in 1) IMSL libraries for multidimensional spline interpolation 2) Numerical Recipes and the several references that Numerical Recipes gives for multidimensional spline interpolation. I am measuring the nonisothermal wake of a flat plate which is thermally stratified for velocities in the 5-10m/s range. Lueptow et al give a very good method for a X-wire calibration via a look-up table, which I can recommend for use. Meyer states that to extend the method of Lueptow et al to a third dimension is a trivial matter (ha, I say). I would use the method of Meyer, but it is less accurate at low velocities. Meyer basically uses the method of Lueptow et al with a linear approximation for the temperature probe calibration, which I don't understand why if the method of Lueptow et al is easily extended to 3-d. It can't be that computationally expensive, can it? Now my questions: 1) Does anyone else do this sort of calibration? 2) Does anyone have a method or reference for 3-d look-up tables that they can recommend? Any help you can give is greatly appreciated. Please respond via e-mail and I can redistribute if others are interested in this same information. -george ================= NeXTMail more than welcome ================== George B. Ross Heavens, I don't like the looks of that gross@stimpy.ame.nd.edu Stimpson J. Cat
Technical Details
Message-ID:
<1992Nov3.141310.27495@news.nd.edu>Path:
arc1-ca.pugleaf.net!sparky!uunet!caen!spool.mu.edu!news.nd.edu!newsShow Full Headers
Complete Article Headers
Newsgroups: sci.geo.fluids Path: arc1-ca.pugleaf.net!sparky!uunet!caen!spool.mu.edu!news.nd.edu!news From: gross@stimpy.ame.nd.edu (George B. Ross) Subject: triple hot wire calibration Message-ID: <1992Nov3.141310.27495@news.nd.edu> Keywords: hot wire, calibration, look-up tables Sender: news@news.nd.edu (USENET News System) Reply-To: gross@stimpy.ame.nd.edu Organization: University of Notre Dame Date: Tue, 3 Nov 1992 14:13:10 GMT Lines: 44