Article View: sci.image.processing
Article #380ANNOUNCEMENT: image, sequence and volume data available by ftp
From: H}kan B}rman
Date: Fri, 14 Aug 1992 09:16
Date: Fri, 14 Aug 1992 09:16
443 lines
14902 bytes
14902 bytes
A number of images, volumes and sequences can be obtained by anonymous
ftp from isy-gw.liu.se (130.236.1.3). The data is located on the
directory /site/src/public/Packages/images/ where also a README-file
describing the data can be found.
I have appended the README at the end of this (semi-regular) posting.
/Hakan
-------------------------------------------------------------------------------
H}kan B}rman | Email: hobo@isy.liu.se
Linkoping University |
Dept. of Electrical Engineering |
Computer Vision Laboratory |
S-581 83 Linkoping | Phone: +13 28 18 85
Sweden | Fax: +13 13 85 26
-------------------------------------------------------------------------------
This is /site/src/public/Packages/images/README.
This file contains the following sections:
How to convert .imf-files
If you have problems
Contents
Description of the directorys
Description of the images
This directory contains image-files (with the extension .imf) and
directorys (with the extension .ic).
All files with the extension .imf are binary. All other files are ascii.
How to convert .imf-files.
==========================
The image files are stored using the file format used at the Computer
Vision Laboratory at Linkoping University. The file format consists of
a header of 512 byte (describing the size, pixel type etc) followed by
the raw image data, pixel by pixel. You will need to do the following
two steps:
1/ Get rid of the header info, eg by standard Unix tools such
as dd (eg dd if=girl.imf of=girl.raw bs=512 skip=1)
2/ Convert the raw image data to your personal image file
format. The dimension of the images are given at the end of
this text file.
If you have problems:
=====================
List of trouble-shooters:
hobo@isy.liu.se
jowi@isy.liu.se
mwe@isy.liu.se
CONTENTS:
=====================
Text-files:
README This file.
ChapelHill1.txt How to get some more interesting volumes.
Stereo.txt Calibration data for the stereo pair in calib.ic
Image Catalogues:
barn.ic colour image
breakfast.ic stereo
calib.ic stereo
frau.ic sequence
heart1.ic sequence
heart2.ic sequence
knee.ic volume
Images:
=========================================
##### Description of the directorys #####
=========================================
barn.ic
=====================================================
Origin: Martin Hedlund
ContextVision
Struers Vision AB, Engelbrektsgatan 22
Linkoping, SWEDEN
History: A colour image with the red, green and blue components stored
in separate files. An outdoor scene from Linkoping, although
it looks more like the countryside.
Format: A directory containing 3 images, (red, green and blue) each file
with 512 rows, 512 columns, 1 unsigned byte/pixel.
Acknowledge: See origin.
breakfast.ic
=====================================================
Origin: CVAP (Computational Vision and Active Perception Laboratory)
at KTH, Stockholm, Sweden.
History: One stereo pair made with CVAPs Head-Eye Robot System.
(Pahlavan & Eklundh, Proc. SPIE Machine Vision and Robotics
Conf., Apr 1992). [This scene has been refered to as `a
typical Swedish breakfast table', but this is not true: Most
of us do NOT have an icosahedron for breakfast. /hb]
Format: A directory containing 2 images, (left and right) each file
with 512 rows, 384 columns, 1 unsigned byte/pixel.
Acknowledge: Jan-Olof Eklundhs CVAP group at KTH, Stockholm, Sweden.
calib.ic
======================================================
Origin:
Wilfried Enkelmann email: enk@iitb.fhg.de
Fraunhofer Institut fuer Informations- und Datenverarbeitung IITB
Fraunhoferstr. 1
D-7500 Karlsruhe 1
GERMANY
History: A stereo pair with ground truth for some of the pixels (see
the text file stereo.txt). Note that the same camera setup is
used in frau.ic.
Format: A directory containing 2 images. Each file
with 512 rows, 512 columns, 1 unsigned byte/pixel.
Acknowledge: See origin.
dodecROT_DC.ic dodecROTdB10 dodecROT_id
================================================
Origin: Computer Vision Laboratory, Link\"oping University,
Link\"oping, Sweden.
History: Synthetic 3D data designed for testing of 3D
line/edge/orientation detectors, see:
@PhdThesis{h92,
author = {L. Haglund},
title = {Adaptive {M}ultidimensional {F}iltering},
school = {Link\"oping University, Sweden},
year = {1992},
address = {S--581 83 Link\"oping, Sweden},
month = {October},
}
10 lines distributed as the vertices of a dodecahedron. The
"dB10" has white gaussian noise added to a SNR of 10 dB.
SNR = 20 log(amp(signal)/sdev(noise)).
The _id sequence contains the true optical flow if the volume
is interpreted as an image sequence.
Format: Directories containing 64 slices (images), each file with 64
rows, 64 columns, 1 unsigned byte/pixel except for the _id
sequence which has 4 bytes/pixel. The first two bytes (a C
short) represent the length of the flow vector. The last two
bytes (a C short) represent the angle of the flow vector and
should be mapped from [-32768, 32767] to [-PI, PI}.
Acknowledge: Leif Haglund.
fleet_div.ic fleet_div_id.ic fleet_trans.ic fleet_trans_id.ic
=============================================================
Origin: David Fleet email: fleet@qucis.queensu.ca
History: These sequences are suitable for comparison of optical flow
algorithms. (The `lenna' of optical flow?) They are described
in:
@Book{fleet92,
author = "David J. Fleet",
title = "Measurement of image velocity",
publisher = "Kluwe Academic Publishers",
year = "1992",
note = "ISBN 0--7923--9198--5"
}
@InProceedings{barron92,
author = "J.L. Barron and D. J. Fleet and S. S.
Beauchemin and T. A. Burkitt",
title = "Performance of Optical Flow Techniques",
booktitle = "Proc. of the CVPR",
year = "1992",
pages = "236--242",
organization = "IEEE",
address = "Champaign, Illinois, USA",
OPTnote = ""
}
Format: Four different directories. _trans and _div contains the
original sequences, while _trans_id and _div_id should contain
the true optical flow (*). The trans sequence has 40 frames
and the div sequence has 39 frames. All of the images have 150
rows and 150 columns. The original sequences have 1 unsigned
byte/pixel. The true OF sequences have 4 bytes/pixel. The
first two bytes (a C short) represent the length of the flow
vector. The last two bytes (a C short) represent the angle of
the flow vector and should be mapped from [-32768, 32767] to
[-PI, PI}.
Acknowledge: See origin.
(*): The true optical flow data was generated here at the Computer
Vision Laboratory but should be identical to the true flow
used in \cite{fleet92,barron92}.
frau.ic
======================================================
Origin:
Wilfried Enkelmann email: enk@iitb.fhg.de
Fraunhofer Institut fuer Informations- und Datenverarbeitung IITB
Fraunhoferstr. 1
D-7500 Karlsruhe 1
GERMANY
History: One of many stereo sequences available from Karlsruhe. A
woman(?) crossing the street.
Format: A directory containing 30 images, ie 15 stereo frames. Each file
with 512 rows, 512 columns, 1 unsigned byte/pixel.
Acknowledge: See origin.
heart1.ic
==================================================
Origin: Tomas Gustavsson, Dept. of Applied Electronics, Chalmers
University of Technology, S - 412 96 Gothenburg, Sweden.
History: Cross-sectional ultrasound sequence revealing the chambers of
the heart. Note that the sequence is cyclic!
Format: A directory containing 16 images, each file with 128 rows, 128
columns, 1 unsigned byte/pixel.
Acknowledge: Tomas Gustavsson, Dept. of Applied Electronics, Chalmers
University of Technology, S - 412 96 Gothenburg, Sweden.
heart2.ic
==================================================
Origin: See heart1.ic
History: See heart1.ic
Format: A directory containing 16 images, each file with 128 rows, 128
columns, 1 unsigned byte/pixel.
Acknowledge: See heart1.ic
knee.ic
================================================
Origin: Data taken on the Siemens Magnetom and provided courtesy of
Siemens Medical Systems, Inc., Iselin, NJ.
History: A 127-slice data set of a human knee. Complete slices are
stored consecutively as a 256 x 256 array. Pixels consist of
2 consecutive bytes making one binary integer. This volume is
part of the Chapel Hill Volume Rendering Test Dataset, Volume I
See the file `ChapelHill1.txt' for a description of how to get
this excellent data set.
Format: A directory containing 127 images, each file with 256 rows,
256 columns, 2 bytes/pixel
Acknowledge: Siemens Medical Systems, Inc., Iselin, NJ.
SoftLab, University of North Carolina, Chapel Hill, NC.
onion.ic
================================================
Origin: Computer Vision Laboratory, Link\"oping University,
Link\"oping, Sweden.
History: Synthetic 3D data designed for testing of 3D
line/edge/orientation detectors, see:
@PhdThesis{b91,
author = {H. B{\aa}rman},
title = {Hierachical Curvature Estimation in Computer Vision},
school = {Link\"oping University, Sweden},
year = {1991},
address = {S--581 83 Link\"oping, Sweden},
month = {September},
note = {Dissertation No 253, ISBN 91--7870--797--8}
}
@PhdThesis{h92,
author = {L. Haglund},
title = {Adaptive {M}ultidimensional {F}iltering},
school = {Link\"oping University, Sweden},
year = {1992},
address = {S--581 83 Link\"oping, Sweden},
month = {October},
}
This volume contains all possible 3D plane orientations for a
wide spatial frequency range. A traveller headed outwards from
the centre and moving in a straight line would experience a
sine wave with decreasing frequency, ie `onion' is a badly
chosen name.
Format: A directory containing 64 slices (images), each file with 64
rows, 64 columns, 1 unsigned byte/pixel.
Acknowledge: Hans Knutsson, Leif Haglund, Hakan Barman.
roadworkC.ic
================================================
Origin: L. Olsson, SAAB-SCANIA, Jonkoping, Sweden
History: A colour sequence. Video recorded from a SAAB 9000 using
super-VHS. Transfered to the digital video standard CCIR 601.
Format: A directory containing 36 frames (108 images). Note that
the sequence is stored in YUV format and NOT RGB! Each frame
has three image files, one for each YUV-component. The
digital video standard (CCIR 601) defines a 4:2:2
sampling, ie 13.5 MHz for luminance and 6.5 MHz for each
of the chrominance components. Because of this the Y
component image has double the width of the U and V
components.
The Y (luminance) images are roadworkC_0.imf, roadworkC_3.imf,
roadworkC_6.imf, etc with 576X720 pixels (1 unsigned byte)
The U and V images have 576X360 1 unsigned byte/pixel.
YUV => RGB conversion:
R= 0.9709*Y - 0.0516*U + 1.4026*B
G= 0.9709*Y - 0.3960*U - 0.7144*B
B= 0.9709*Y + 1.7214*U - 0.0001*B
Acknowledge: SAAB-SCANIA.
tbrus3D.ic
================================================
Origin: Computer Vision Laboratory, Link\"oping University,
Link\"oping, Sweden.
History: Synthetic 3D white gaussian noise. Sdev=32.1
@PhdThesis{b91,
author = {H. B{\aa}rman},
title = {Hierachical Curvature Estimation in Computer Vision},
school = {Link\"oping University, Sweden},
year = {1991},
address = {S--581 83 Link\"oping, Sweden},
month = {September},
note = {Dissertation No 253, ISBN 91--7870--797--8}
}
@PhdThesis{h92,
author = {L. Haglund},
title = {Adaptive {M}ultidimensional {F}iltering},
school = {Link\"oping University, Sweden},
year = {1992},
address = {S--581 83 Link\"oping, Sweden},
month = {October},
}
Format: A directory containing 64 slices (images), each file with 64
rows, 64 columns, 1 unsigned byte/pixel.
Acknowledge: Hans Knutsson.
=====================================
##### Description of the images #####
=====================================
bredploop.imf
=====================================
Origin: Computer Vision Lab. Link\"oping University, Link\"oping, Sweden.
History: Designed for testing of line/edge/orientation detectors, see:
@PhdThesis{h92,
author = {L. Haglund},
title = {Adaptive {M}ultidimensional {F}iltering},
school = {Link\"oping University, Sweden},
year = {1992},
address = {S--581 83 Link\"oping, Sweden},
month = {October},
}
This image covers a wider frequency range than ploop.imf (see below)
Format: 512 rows, 512 columns, 1 unsigned byte/pixel.
Acknowledge: Leif Haglund & Hans Knutsson
girl.imf
=====================================
Origin: The well-known `Lenna' image in BW. The grey level has been
computed from the RGB images in the image data base of the USC
Image Processing Institute.
History: From Playboy November '74. (I will NOT post her address /hb).
Format: 512 rows, 512 columns, 1 unsigned byte/pixel.
NOTE! This image is currently not available by ftp. We can use it
ourselves but NOT distribute it (USCIPI report 1060).
ploop.imf
=====================================
Origin: Computer Vision Lab. Link\"oping University, Link\"oping, Sweden.
History: Designed for testing of line/edge/orientation detectors, see:
@phdthesis{k82,
AUTHOR={Hans Knutsson},
TITLE={Filtering and Reconstruction in Image Processing},
SCHOOL={Link\"oping University, Sweden},
YEAR={1982},
NOTE={Diss. No. 88}}
Format: 512 rows, 512 columns, 1 unsigned byte/pixel.
Acknowledge: Hans Knutsson.
tbrus.imf
================================================
Origin: Computer Vision Laboratory, Link\"oping University,
Link\"oping, Sweden.
History: Synthetic 2D white gaussian noise. Sdev=32.1 (same data as
tbrus3D.ic!)
Format: see ploop.imf
Acknowledge: see ploop.imf
--
-------------------------------------------------------------------------------
H}kan B}rman | Email: hobo@isy.liu.se
Linkoping University |
Technical Details
Message-ID:
<hobo.713783785@isy.liu.se>Path:
arc1-ca.pugleaf.net!sparky!uunet!mcsun!sunic!liuida!isy!isy.liu.se!hoboShow Full Headers
Complete Article Headers
Newsgroups: sci.image.processing Path: arc1-ca.pugleaf.net!sparky!uunet!mcsun!sunic!liuida!isy!isy.liu.se!hobo From: hobo@isy.liu.se (H}kan B}rman) Subject: ANNOUNCEMENT: image, sequence and volume data available by ftp Message-ID: <hobo.713783785@isy.liu.se> Summary: description of how to obtain image data from isy.liu.se Keywords: image sequence volume ftp Organization: Dept of EE, University of Linkoping Date: 14 Aug 92 09:16:25 GMT Lines: 443