alpha@werple.apana.org.au writes: >..., since I couldnt find a peizo electric device that would do what I needed (ie: deform to a given voltage). So... to any people who HAVE built one, what did you use? Staveley Sensors Inc. 203-289-5428 PZT-5A ceramic tube Nickle plated 90-degree quadrant length 0.75, OD 0.125, Wall thickness 0.022 (all units in inches) $174.00 (the most expensive part in my STM) And read the literature, the scan rate can be quite fast.
Technical Details
Message-ID:
<Jan.26.23.45.21.1993.23049@planchet.rutgers.edu>Path:
arc1-ca.pugleaf.net!sparky!uunet!news.univie.ac.at!scsing.switch.ch!univ-lyon1.fr!ghost.dsi.unimi.it!rpi!uwm.edu!linac!att!cbnewsk!cbnewsj!att-out!rutgers!igor.rutgers.edu!planchet.rutgers.edu!nanotechShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!news.univie.ac.at!scsing.switch.ch!univ-lyon1.fr!ghost.dsi.unimi.it!rpi!uwm.edu!linac!att!cbnewsk!cbnewsj!att-out!rutgers!igor.rutgers.edu!planchet.rutgers.edu!nanotech From: ear@clockwise.att.com Newsgroups: sci.nanotech Subject: STM piezo elements Message-ID: <Jan.26.23.45.21.1993.23049@planchet.rutgers.edu> Date: 27 Jan 93 04:45:22 GMT Sender: nanotech@planchet.rutgers.edu Lines: 14 Approved: nanotech@aramis.rutgers.edu