Article View: sci.physics.fusion
Article #1034Re: Trying to keep clean
From: Carl Ijames
Date: Tue, 15 Dec 1992 08:40
Date: Tue, 15 Dec 1992 08:40
43 lines
2333 bytes
2333 bytes
In article <921211171031.20400aba@FNALD.FNAL.GOV>, ames!FNALD.FNAL.GOV!DROEGE wrote: [munch] > here, some has been sent privately. Us commercial glass cleaner some say > (contain chromic acid), others say DON'T USE CHROMIC ACID! So I have to look The problem with chromic acid is that chromium(VII) is toxic and not nice to put down drains. Chromic acid is a great glass cleaner, but other, alkaline systems are as good and less toxic. > My brother is pushing me to build a vapor degreaser. The plan at the moment > is to buy a 24 cup coffee maker and to put a copper cooling coil in the top of > it and to load it with perchlorethylene. I guess this will then be a > perchlorethylene percolator. (The basket is of course removed.) This should > work great to clean the Lithium. The problem is then to get it into an inert > atmosphere before it oxidizes. Of course, the lithium will react with the perchloroethylene, especially after you heat it up. Why not rinse the oil off of the lithium with xylene or hexane, leave it covered with a small amount of xylene, place it in your glove bag, and then remove it from the solvent and let it dry? If you keep a flow of argon through the bag the solvent vapors will be swept out. > I bought a box of vinyl gloves a while back with the idea of making my own > glove box. Now I am worried that they are not safe to use as they are likely > full of plasticizer(sp?). Would rubber gloves be better? We use thin cotton gloves to handle pieces (like sources and lenses) that go into mass spectrometer vacuum systems. This assumes the gloves are clean and that we will not sweat through them. The gloves are cleaned by washing in water, then acetone, then hexane. > Please keep all the good advice coming. > > Tom Droege We'll keep it coming, you have to decide how good it is. Regards, Carl Ijames
Technical Details
Message-ID:
<ijames-151292032846@156.40.188.220>Path:
arc1-ca.pugleaf.net!sparky!uunet!nih-csl.dcrt.nih.gov!NewsWatcher!userReferences:
<921211171031.20400aba@FNALD.FNAL.GOV>Show Full Headers
Complete Article Headers
Newsgroups: sci.physics.fusion Path: arc1-ca.pugleaf.net!sparky!uunet!nih-csl.dcrt.nih.gov!NewsWatcher!user From: ijames@helix.nih.gov (Carl Ijames) Subject: Re: Trying to keep clean Message-ID: <ijames-151292032846@156.40.188.220> Followup-To: sci.physics.fusion Sender: postman@alw.nih.gov (AMDS Postmaster) Organization: NIH References: <921211171031.20400aba@FNALD.FNAL.GOV> Date: Tue, 15 Dec 1992 08:40:12 GMT Lines: 43