Article View: sci.physics.fusion
Article #1257Re: List
From: Hoyt A. Stearns jr.
Date: Thu, 07 Jan 1993 18:14
Date: Thu, 07 Jan 1993 18:14
109 lines
5202 bytes
5202 bytes
In article <930105144432.20a07695@FNALD.FNAL.GOV> DROEGE@fnald.fnal.gov writes: >Hoyt A Stearns writes: > >"I think you forgot one: My Pd Pt cell has a hydrocap recombiner, and was >evacuated after Pd charging. The head pressure is very low." > >Does it stay low? Under these conditions, either outgassing or new absorption Yes. It has been "low" for a year. The hydrocap is quite efficient, I guess. DISCLAIMER: I don't have any where near the equipment, time, or money available to me as you have. This is a "back burner" project. If something is convenient to try, I'll do it, without necessarily having any hypothesis. The electrolyte is 100g 99.9% D20, 1 pellet of Li metal, and a trace of CS2. The cell was evacutated to prevent the Li0D from absorbing C02 to form LiCO3; to prevent H20 exchange with D20, and, of course, the cell is sealed because I can't afford to keep buying D20. Because of previous experiments with very high voltages and currents, I definitely don't want very much combustible gas in the head space, and the hydrocap obliges. The cell consists of 2 in^2 of platinum ribbon wrapped on a polyethylene semi-permeable membrane 1" dia. In the center is a 5g Pd rod. At the top fluid surface is a 10 g Pd disk, half immersed, flat side down. All electrodes are wired with Pt wire mechanically connected (no brazing). The cell is sealed with parafilm around a 2" rubber stopper. Normally I have the two Pd pieces connected together electrically, but I have varied the currents to change the current distribution in the electrolyte. > >Note anything kills the vacuum. If there is D2 absorption then the excess O2 >kills the vacuum. If the cathode outgasses D2 then that kills the vacuum >since there is no O2 to combine it on the catalyst. > I wouldn't say my "low pressure" is a vacuum. It is, of course, higher than the vapor pressure of D20 at room temperature, but substantially lower than atmospheric (but I don't have calibrated guage). A bit of history: This cell has been sealed for >2YR, and been through many different experimental conditions. It has been operating with 5 volts, 42 ma for a year. It gets warm to the touch every couple of weeks for a day or so (There is no calorimeter, so this counts for nothing). Previously (>1 year ago): The cell has been run with 10 amps in a water cooled jacket, which boils the electrolyte and expels vapor out a check valve through a bubbler, due to thermal expansion, boiling etc. (this leaves low pressure when the steam condenses); It has been pulsed with 1000V high current pulses once a second for a while (interesting and spectacular display of red plasma--this probably creates ultrasonic shock waves. It was violent enough I was worried about shattering the container. It also created a black sediment of unknown composition); It has been run with an immersed ultrasonic generator (the only effect I saw was the electrolysis bubbles changed in size, as I recall there were fewer of them, but larger, making it easier to see inside). It has been run surrounded with a wire solenoid, with pulsed high current applied, constant DC current, and sinuosoidal AC.(The idea here was to induce large circulating currents in the Pd) (A previous cell had electrical connections on both ends of the Pd rod, and various combinations of currents through the rod and currents to the electrolyte were tried, including AC and DC). It has been run raised to + and - 40KV (the whole apparatus).; It has been run with DC offset AC electrolysis current, the AC varying from 60 HZ to several MHz. ____ Things I'd like to try but haven't yet: Mount a Pd rod in two bearings to make an axle, then angularly misalign one bearing, and rotate the Pd to create alternating compression and rarefaction at the perimeter of the rod. Rotate the Pd rod at high speed to create a boundary layer of electrolyte. Rotate the whole apparatus about the Pd rod (this will cause the bubbles to migrate toward the rod). Put the whole apparatus in an ultra-centrifuge (this will cause the bubbles to be of much higher pressure, and probably rise faster. Fire a high power pulse laser to a spot on the Pd. Ultrasonically excite the Pd rod itself. Explosively compress a D charged Pd sphere. -- Hoyt A. Stearns jr.|hoyt@ | International Society of Unified Science| 4131 E. Cannon Dr. |isus.tnet.com -| Advancing Dewey B. Larson's Reciprocal | Phoenix, AZ. 85028 |ncar!enuucp! | System- a unified physical theory. | voice_602_996_1717 telesys!isus!hoyt The Universe in two postulates__________|
Technical Details
Message-ID:
<1993Jan7.181458.5320@isus.UUCP>Path:
arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!cs.utexas.edu!asuvax!ennews!telesys!isus!hoytReferences:
<930105144432.20a07695@FNALD.FNAL.GOV>Show Full Headers
Complete Article Headers
Newsgroups: sci.physics.fusion Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!cs.utexas.edu!asuvax!ennews!telesys!isus!hoyt From: hoyt@isus.UUCP (Hoyt A. Stearns jr.) Subject: Re: List Message-ID: <1993Jan7.181458.5320@isus.UUCP> Followup-To: sci.physics.fusion Summary: Sealed "cold fusion" cell. Keywords: P&F, recombiner, sealed cell Organization: International Society of Unified Science References: <930105144432.20a07695@FNALD.FNAL.GOV> Date: Thu, 7 Jan 1993 18:14:58 GMT Lines: 109