Article #1250Re: Question about dimmer switch and lamp.
From: Jim Easton
Date: Thu, 16 Apr 1992 19:06
Date: Thu, 16 Apr 1992 19:06
69 lines
3463 bytes
3463 bytes
gsteckel@vergil.East.Sun.COM (Geoff Steckel - Sun BOS Hardware CONTRACTOR) writes: >> Given an incandescent lamp with a dimmer switch. The lamp is on. >>... >> switch up, no matter how slow, the light always comes on rather >> suddenly and much brighter than in the reverse process . >Yes, but it has to do with the circuit triggering the triac. ... I disagreed with this but I am a great believer in letting experiment settle these issues so last night I pulled the dimmer out of our dinning room wall and wired it up on the kitchen table with a couple of meters to see what was going on. Sadly, it turns out I was wrong, at least partly, and that Geoff is probably right - it is the hysteresis in the triac that is doing it. (I hate being wrong) My explanation was that it arises from the non-linearity of the light bulb resistance with temperature. Had I been correct then as I turned the control from zero up to the point where the bulb comes on I would have seen the current slowly increasing and at the point where the bulb comes on the current would drop. Instead the current remained at the "quiescent" value until the light came on at which point it suddenly jumped to values shown below. Similarly going down when the bulb goes out the current should have risen slighly but it dropped to about 1 Ma. Interestingly immediately after turning the control to zero the current drops to about 1 Ma but then as time goes on (~30 seconds) the current rises to several Ma. On one occasion the control was turned to zero and I was sitting there wondering what I would do next when the bulb came on, full power. I turned the control just slightly off zero and it went out again. Would Geoff have an explanation for what happened there? Following are the numbers that I got - if anyone's interested. I have arranged them in order of decreasing bulb resistance. current bulb volts calculated bulb (Ma) resistance 40 Watt bulb full on 335 115 343 intermediate value 289 60 207 up from zero - bulb on 237 35 147 down - bulb goes off ~120 ~6 50 all the way down 1-4 ~0 .03 (measured) 100 Watt bulb full on 850 115 135 intermediate 717 60 84 up from zero - bulb on 590 36 61 down - bulb goes off ~280 ~5 17 all the way down 1-5 ~0 .013 (measure) The reason I said I was only partly wrong is because the bulb resistance is extremely non-linear and I have seen this effect using a rheostat but that was quite a number of years ago. Unfortunately I didn't have a rheostat of suitable value but I am going to try to round one up. In the meantime perhaps someone who does have a rheostat of the right value could try it and let us know what happens. My expectation is that one would see the effect but it would be much less pronounced than it is with the triac. Jim
Technical Details
Message-ID:
<jim.703451166@st-michael>Path:
arc1-ca.pugleaf.net!sparky!uunet!elroy.jpl.nasa.gov!decwrl!access.usask.ca!kakwa.ucs.ualberta.ca!alberta!jimReferences:
<1992Apr11.112952.583@crd.ge.com> <jim.703196344@st-michael> <sd6omINNkh6@seven-up.East.Sun.COM>Show Full Headers
Complete Article Headers
Newsgroups: sci.physics Path: arc1-ca.pugleaf.net!sparky!uunet!elroy.jpl.nasa.gov!decwrl!access.usask.ca!kakwa.ucs.ualberta.ca!alberta!jim From: jim@cs.UAlberta.CA (Jim Easton) Subject: Re: Question about dimmer switch and lamp. Message-ID: <jim.703451166@st-michael> Sender: news@cs.UAlberta.CA (News Administrator) Nntp-Posting-Host: st-michael.cs.ualberta.ca Organization: University of Alberta, Edmonton, Canada References: <1992Apr11.112952.583@crd.ge.com> <jim.703196344@st-michael> <sd6omINNkh6@seven-up.East.Sun.COM> Distribution: na Date: Thu, 16 Apr 1992 19:06:06 GMT Lines: 69