Apologies to all as there was a "strange" incorrect link under the XDS software.
The corrected infomation is given below and this is also on the
webpage as well.
http://www.ccp14.ac.uk/solution/ccd_software/
XDS - by Wolfgang Kabsch
To receive information on how to obtain the XDS software
(is free of charge for academic users processing synchrotron data)
E-mail Wolfgang Kabsch at: kabsch@otto.mpimf-heidelberg.mpg.de
Some of the information on XDS is below:
" The program package XDS has been developed for the reduction of single-
crystal diffraction data recorded on a planar detector by the rotation
method using monochromatic X-rays.
XDS is free of charge for academic users processing synchrotron data.
At present, XDS can process images generated by the following detectors:
SIEMENS - (Siemens/Nicolet) multiwire detector
MAR - marresearch (X-ray Research) imaging plate detector (old)
MAR345 - marresearch (X-ray Research) imaging plate detector (new)
RAXIS - R-AXIS2 and R-AXIS4 imaging plate detector
MAC - MacScience imaging plate detector, ENRAF NONIUS DIP-series
CCDD2AM - CCD-detector at ESRF Grenoble (beamline D2AM)
ESRF - CCD-detector at ESRF Grenoble (beamline 3)
VIDEMETRIX - CCD-detector at Brandeis (designed by Walter Phillips)
CCDCHESS - CCD-detector at CHESS and MAR CCD-detector at BROOKHAVEN
CCDBRANDEIS - CCD-detector at Brandeis (1024 X 1024) and Brookhaven
SMART - CCD-detector at BASF Ludwigshafen (BRUKER format)
ADSC - Quantum4 CCD-detector at Lund (SMV-format)
Executables of XDS are available for SGI, alpha (OSF/1), and linux
(i686,m486) as compressed tar-files"
---------
(again, further corrections on the above and information on any other source
code or programs appreciated)
Lachlan.
======================
Lachlan M. D. Cranswick
Collaborative Computational Project No 14 (CCP14)
for Single Crystal and Powder Diffraction
Daresbury Laboratory, Warrington, WA4 4AD U.K
Tel: +44-1925-603703 Fax: +44-1925-603124
E-mail: l.cranswick@dl.ac.uk Ext: 3703 Room C14
http://www.ccp14.ac.uk
Technical Details
Message-ID:
<l.cranswick.479.04EE25EE@dl.ac.uk>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailShow Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: f804b,2699ef5faae2ef31,start X-Google-Attributes: gidf804b,public X-Google-Thread: fcf0b,2699ef5faae2ef31,start X-Google-Attributes: gidfcf0b,public From: l.cranswick@dl.ac.uk (Lachlan Cranswick) Subject: Erratum: Available CCD Control and CCD processing/crunching software Date: 2000/04/20 Message-ID: <l.cranswick.479.04EE25EE@dl.ac.uk> X-Deja-AN: 613401787 X-Complaints-To: newsmaster@dl.ac.uk X-Trace: mserv2.dl.ac.uk 956195764 2744 148.79.160.252 (20 Apr 2000 01:56:04 GMT) Organization: CCP14 Project, Daresbury Laboratory, UK NNTP-Posting-Date: 20 Apr 2000 01:56:04 GMT Newsgroups: sci.techniques.xtallography,bionet.xtallography