Re: APC SmartUPS problem

#242
From: Paul Hopwood
Date: Fri, 11 Jun 2004 23:19
21 lines
2035 bytes
"Graham W" <graham@his.com.puter.INVALID> wrote:

>>> I've got a new battery on order; Yuasa part worked out half the price
>>> of an APC replacement.
 
>> Battery arrived today, was fitted and appears to have fixed the
>> problem.  Thanks to everyone who offered advice.

>It would be worth checking the terminal voltage under charging 
>conditions to make sure that the death of its predecessor wasn't 
>down to over-charging. 13.8V is often quoted as suitable for
>sealed lead-acid batteries.

According to the PowerChute software the UPS itself reports the
voltage at 13.85V.  Any reason I should mistrust it?

The UPS was manufactured in 1999 and, to the best of my knowledge, was
still on the original battery so probably just died of old age.  :)

-- 
>iv< Paul >iv<
Technical Details
Message-ID: <4bfkc0tp79ta5cir8nvtjas5hejp6961md@4ax.com>
Path: arc1-ca.pugleaf.net!g2news1.google.com!news2.google.com!proxad.net!213.200.89.82.MISMATCH!tiscali!newsfeed1.ip.tiscali.net!newsfeed00.sul.t-online.de!t-online.de!kibo.news.demon.net!news.demon.co.uk!demon!not-for-mail
References: <jfq9c01kogmrku8hedjt5hrb4k4e8ea1pj@4ax.com> <MPG.1b2f1208d82dee6a989728@news-text.blueyonder.co.uk> <k2vbc016h75ciae8ukukh91oq9kj03e0fv@4ax.com> <abfhc0pjs64qftmbhjnpg1s03ohbrh433u@4ax.com> <40c8f450$0$533$ed2619ec@ptn-nntp-reader02.plus.net>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: 1063f0,32a19d7fea2ee17a
X-Google-Thread: 1036bc,c36563a0f1637fe5
X-Google-Attributes: gid1063f0,gid1036bc,public
Path: arc1-ca.pugleaf.net!g2news1.google.com!news2.google.com!proxad.net!213.200.89.82.MISMATCH!tiscali!newsfeed1.ip.tiscali.net!newsfeed00.sul.t-online.de!t-online.de!kibo.news.demon.net!news.demon.co.uk!demon!not-for-mail
From: Paul Hopwood <paul@hopwood.org.uk>
Newsgroups: uk.comp.homebuilt,demon.tech.pc
Subject: Re: APC SmartUPS problem
Date: Sat, 12 Jun 2004 00:19:45 +0100
Organization: hopwood.org.uk
Lines: 21
Message-ID: <4bfkc0tp79ta5cir8nvtjas5hejp6961md@4ax.com>
References: <jfq9c01kogmrku8hedjt5hrb4k4e8ea1pj@4ax.com> <MPG.1b2f1208d82dee6a989728@news-text.blueyonder.co.uk> <k2vbc016h75ciae8ukukh91oq9kj03e0fv@4ax.com> <abfhc0pjs64qftmbhjnpg1s03ohbrh433u@4ax.com> <40c8f450$0$533$ed2619ec@ptn-nntp-reader02.plus.net>
NNTP-Posting-Host: wall.demon.co.uk
Mime-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
X-Trace: news.demon.co.uk 1086995988 3142 62.49.6.3 (11 Jun 2004 23:19:48 GMT)
X-Complaints-To: abuse@demon.net
NNTP-Posting-Date: Fri, 11 Jun 2004 23:19:48 +0000 (UTC)
X-Newsreader: Forte Agent 2.0/32.652