Article View: alt.dcom.telecom
Article #408Problems with Telebit modems and three Xenix Systems
From: Mark Seiffert
Date: Thu, 30 Apr 1992 22:10
Date: Thu, 30 Apr 1992 22:10
93 lines
5169 bytes
5169 bytes
I am unable to solve a problem with three systems with Telebit modems and SCO Xenix systems. My system is a 486/33 with a Telebit TB+ on a specialIX port running SCO Xenix 386. Its a dog with an average of 32 Users, the response time is bad. I am not sure how this would affect the modem, the SI board is an intelligent board with RTS/CTS flow control. System A is a 386 with a T1000 on COM1: with the interface locked at xxxx baud System B is a 286/12 with a T1000 on COM1:, the interface is locked at xxxx baud When system A tries to send a 20K file to system B using UUCP, the line is lost. When system A tries to get the file from system B using UUCP, the line is lost. All systems are set with m2s61=255, micro-packets disabled and tone before packets, the modems are not retraining at the point where the error occurs. On my system I have s58=2s68=2, on system B, s58=3s68=255, on system A, s58=3s68=3. When I send a 1.2MB file to system A, the file transfers fine, when uucp changes to to slave mode and tries to retrieve a 170K file, the line is lost. When System A calls me and attempts to send the file, the line is lost. When I try to download using Zmodem from A to me with Xmodem spoofing on (because I was going to try Xmodem if Zmodem failed), there were errors but the file made it. When I uploaded the same file to system B using Xmodem with Xmodem spoofing, the transfer took a long time, had a large number of errors but it finally made it. With Xmodem, there were a lot of pauses when nothing was being sent. With UUCP, the transfer procedes for a while and all of a sudden I start receiving alarms, eventually it will abort with line lost. I had thought that 'spoofing' meant that the modems would take care of error correction between themselves and return the user an error free data transmission. Why am I seeing errors with Xmodem? What is going on here? Can you help me? Does anyone have list of the undocumented features in the Telebit modems? I know of some of the information for disabling micro-packets and adding tone before packets, and I remember some S registers have undocumented 254 and 255 values. This is the register setting for my Tbit+ E1 F1 M2 Q4 T V1 X1 Version BA4.00 S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=060 S08=002 S09=006 S10=007 S11=070 S12=050 S45=255 S47=004 S48=000 S49=000 S50=255 S51=005 S52=001 S53=001 S54=002 S55=000 S56=017 S57=019 S58=002 S59=000 S60=000 S61=100 S62=003 S63=001 S64=000 S65=000 S66=001 S67=000 S68=002 S90=000 S91=000 S92=001 S95=002 S100=000 S101=000 S102=000 S104=000 S110=001 S111=020 S112=001 S120=012 S121=000 This is the register setting for system A's T1000 %E0 F1 M0 Q0 P V1 W0 X1 Y0 &P0 &T4 Version FA2.10 %S00=001 S01:001 S02=043 S03=013 S04=010 S05=008 S06=002 S07=040 S08=002 S09=006 %S10=007 S11=070 S12=050 S18=000 S25=005 S38=000 %S41=000 S45:255 S47=004 S48=000 S49=000 %S50=000 S51:005 S52:002 S54:003 S55:003 S56=017 S57=019 S58=003 S59=000 %S60=000 S61=150 S62=003 S63=001 S64=000 S65=000 S66:001 S67=000 S68=255 S69=000 %S90=000 S91=000 S92=000 S94=001 S95=000 S96=001 %S100=000 S101=000 S104=000 %S111:030 S112=001 %S121=000 S130=002 S131:001 S255=001 This is the register setting for system B's T1000 %E0 F1 M0 Q0 P V1 W0 X1 Y0 &P0 &T4 Version FA2.10 %S00=001 S01:001 S02=043 S03=013 S04=010 S05=008 S06=002 S07=040 S08=002 S09=006 %S10=007 S11=070 S12=050 S18=000 S25=005 S38=000 %S41=000 S45:255 S47=004 S48=000 S49=000 %S50=000 S51:005 S52:002 S54:003 S55:003 S56=017 S57=019 S58=003 S59=000 %S60=000 S61=150 S62=003 S63=001 S64=000 S65=000 S66:001 S67=000 S68=255 S69=000 %S90=000 S91=000 S92=000 S94=001 S95=000 S96=001 %S100=000 S101=000 S104=000 %S111:030 S112=001 %S121=000 S130=002 S131:001 S255=001 --- ----------------------------------------------------------------------------- Mark Seiffert UUNet: mark@delta1.UUCP Delta Systems InterNet: mark%delta1@rex.cs.tulane.edu New Orleans, LA 70002 Voice: +1 504 837 9835 Fax: +1 504 837 9838
Technical Details
Message-ID:
<4@delta1.UUCP>Path:
arc1-ca.pugleaf.net!sparky!uunet!spool.mu.edu!tulane!rex!delta1!markShow Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 10beba,d410a23a857c77ca,start X-Google-Attributes: gid10beba,public X-Google-Thread: 10c7e6,d410a23a857c77ca,start X-Google-Attributes: gid10c7e6,public X-Google-Thread: fa2d8,d410a23a857c77ca,start X-Google-Attributes: gidfa2d8,public X-Google-Thread: 1122ea,d410a23a857c77ca,start X-Google-Attributes: gid1122ea,public X-Google-Thread: 1126ff,d410a23a857c77ca,start X-Google-Attributes: gid1126ff,public X-Google-ArrivalTime: 1992-04-30 15:10:25 PST Path: arc1-ca.pugleaf.net!sparky!uunet!spool.mu.edu!tulane!rex!delta1!mark From: mark@delta1.UUCP (Mark Seiffert) Newsgroups: alt.dcom.telecom,biz.comp.telebit,biz.sco.general,comp.dcom.modems,comp.unix.xenix.sco Subject: Problems with Telebit modems and three Xenix Systems Keywords: telebit, modem, sco, xenix Message-ID: <4@delta1.UUCP> Date: 30 Apr 92 22:10:25 GMT Article-I.D.: delta1.4 Followup-To: comp.unix.xenix.sco Organization: My Organization, Inc., Hometown, ST Lines: 93