"sticks" <ksbutler@iinet.net.au> wrote in message
news:41ce65cf$0$14450$5a62ac22@per-qv1-newsreader-01.iinet.net.au...
> Hi all ,
>
> My pool pump has been playing up for a day or two , runs for an
> hour or so then shuts down , (overheating)
> I have taken motor out and the starter capacitor is ruptured i think it is
> 60uF 450VAC cant read much else , motor is a 4.3Amp  Model LTP750 made bY
> ONGA pumps .
> My questions are
>
> 1. Should i just change starter capacitor and refit
> 2. What could cause overheat problem ( bearings aside)
> 3. Do i need exact replacement capacitor
>
> thanks
>
    Don't know the particular motor, but it seems possible that the failed
capacitor is a "run" capacitor which should be constantly  in circuit with
the second "run" winding  to provide phase shift to that winding.  The motor
would be in essence a pseudo two phase motor.  Failure of the capacitor
would explain the overheating.  The voltage rating of 450v also indicates a
"run" cap, but 60 uf seems a bit high.??

Failure of a "start" cap would mean the motor would not start, just hum &
heat up.  I would expect a "start" cap to have a value of 150-200uf & 250v.

Have you considered contacting ONGA or one of their agents?
-- 
Regards, Chas.


To Email, replace 'xxx' with tango papa golf.
Technical Details
Message-ID: <41cfd840$1@dnews.tpgi.com.au>
Path: arc1-ca.pugleaf.net!g2news1.google.com!news1.google.com!newsread.com!newsprint.newsread.com!newsfeed00.sul.t-online.de!t-online.de!newsfeed.freenet.de!nntp.gblx.net!nntp3.phx1!dnews.tpgi.com.au!tpg.com.au!not-for-mail
References: <41ce65cf$0$14450$5a62ac22@per-qv1-newsreader-01.iinet.net.au>

Show Full Headers
Complete Article Headers
X-Google-Thread: 10d137,9daf7dc9c36a4a4d
X-Google-Thread: 103407,9daf7dc9c36a4a4d
X-Google-Attributes: gid10d137,gid103407,public
X-Google-Language: ENGLISH,ASCII-7-bit
From: "Chas" <umlaut@xxx.com.au>
Newsgroups: alt.engineering.electrical,aus.electronics
References: <41ce65cf$0$14450$5a62ac22@per-qv1-newsreader-01.iinet.net.au>
Subject: Re: pool motor starter cap
Date: Mon, 27 Dec 2004 20:39:55 +1100
Lines: 37
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2800.1437
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1441
NNTP-Posting-Host: 60.240.12.118
X-Original-NNTP-Posting-Host: 60.240.12.118
Message-ID: <41cfd840$1@dnews.tpgi.com.au>
X-Trace: dnews.tpgi.com.au!tpg.com.au 1104140352 60.240.12.118 (27 Dec 2004 20:39:12 +1100)
Path: arc1-ca.pugleaf.net!g2news1.google.com!news1.google.com!newsread.com!newsprint.newsread.com!newsfeed00.sul.t-online.de!t-online.de!newsfeed.freenet.de!nntp.gblx.net!nntp3.phx1!dnews.tpgi.com.au!tpg.com.au!not-for-mail