Mike McCarty wrote in message <8alnpa$pki$1@relay1.dsccc.com>...
>In article <8alm5q$g85$1@copland.udel.edu>,
>Ron Dozier <dozier@copland.udel.edu> wrote:
>)In article <89smse$fkl$1@news.cz.js.cn>, peter <asdc@bigfoot.com> wrote:
>)>Hi,can anyone tell me what's the general difference between
>)>instrumental amplifier and operational amplifier? what kind
>)>of application does each amplifier designed for?what kind of behaviors or
>)>characters we could expect when using them in application
>)>
>)
>)I'll tak a stab at this question.  An instrumentation amp geneally
>)amplifies the differnece between it's inputs in the presence of a large
>)common mode signal. They may have an extremely low bandwith.
>
>This is good.
>
>)
>)An operational amplifier on the other hand is a general purpose building
>)block and is single ended.
>
>This is wrong.
>
>)A typical use for an IA is thermocouple signal conditioning or bridge
>)amplifier and data acquisition where ground loops are a problem.
>)>
>)
>)Ron
>)
>
>
>The difference between an op-amp and an instrumentation amp is quite
>simple: an instrumentation amp is an optimized op-amp. It is normally
>built out of more than one op amp. It provides
>
> low leakage
> low offset
> low drift (with temperature and time)
> high common-mode rejection
>
>That's about it.

Don't forget that an instrumentation amp is designed to provide known gain
whereas an op-amp is merely designed to provide extremely high gain.
Technical Details
Message-ID: <scste19qa5n33@corp.supernews.com>
Path: arc1-ca.pugleaf.net!unknown!not-for-mail
References: <89smse$fkl$1@news.cz.js.cn> <8alm5q$g85$1@copland.udel.edu> <8alnpa$pki$1@relay1.dsccc.com>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: 109f9b,ad83af236ce47a65
X-Google-Attributes: gid109f9b,public
X-Google-Thread: 112d1e,ad83af236ce47a65
X-Google-Attributes: gid112d1e,public
X-Google-Thread: 107cee,ad83af236ce47a65
X-Google-Attributes: gid107cee,public
X-Google-Thread: 10d137,ad83af236ce47a65
X-Google-Attributes: gid10d137,public
X-Google-Thread: 1118be,ad83af236ce47a65
X-Google-Attributes: gid1118be,public
X-Google-Thread: 111d0a,ad83af236ce47a65
X-Google-Attributes: gid111d0a,public
X-Google-Thread: 10026f,c4ce15d3e10cd212
X-Google-Attributes: gid10026f,public
X-Google-Thread: 100bb0,c4ce15d3e10cd212
X-Google-Attributes: gid100bb0,public
From: "William L. Bahn" <wbahn@uswest.net>
Subject: Re: difference between instrumental amplifier and operational amplifier
Date: 2000/03/14
Message-ID: <scste19qa5n33@corp.supernews.com>
X-Deja-AN: 597419253
References: <89smse$fkl$1@news.cz.js.cn> <8alm5q$g85$1@copland.udel.edu> <8alnpa$pki$1@relay1.dsccc.com>
Organization: Posted via Supernews, http://www.supernews.com
X-MimeOLE: Produced By Microsoft MimeOLE V4.72.3110.3
Newsgroups: alt.engineering.electrical,cn.bbs.sci.electronics,misc.industry.electronics,misc.industry.utilities.electric,sci.electronics.basics,sci.electronics.components,sci.electronics.design,sci.electronics.misc
X-Complaints-To: newsabuse@supernews.com