2894 bytes
Mike McCarty wrote in message <8alnpa$pki$1@relay1.dsccc.com>... >In article <8alm5q$g85$1@copland.udel.edu>, >Ron Dozier <dozier@copland.udel.edu> wrote: >)In article <89smse$fkl$1@news.cz.js.cn>, peter <asdc@bigfoot.com> wrote: >)>Hi,can anyone tell me what's the general difference between >)>instrumental amplifier and operational amplifier? what kind >)>of application does each amplifier designed for?what kind of behaviors or >)>characters we could expect when using them in application >)> >) >)I'll tak a stab at this question. An instrumentation amp geneally >)amplifies the differnece between it's inputs in the presence of a large >)common mode signal. They may have an extremely low bandwith. > >This is good. > >) >)An operational amplifier on the other hand is a general purpose building >)block and is single ended. > >This is wrong. > >)A typical use for an IA is thermocouple signal conditioning or bridge >)amplifier and data acquisition where ground loops are a problem. >)> >) >)Ron >) > > >The difference between an op-amp and an instrumentation amp is quite >simple: an instrumentation amp is an optimized op-amp. It is normally >built out of more than one op amp. It provides > > low leakage > low offset > low drift (with temperature and time) > high common-mode rejection > >That's about it. Don't forget that an instrumentation amp is designed to provide known gain whereas an op-amp is merely designed to provide extremely high gain.
Technical Details
Message-ID:
<scste19qa5n33@corp.supernews.com>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<89smse$fkl$1@news.cz.js.cn> <8alm5q$g85$1@copland.udel.edu> <8alnpa$pki$1@relay1.dsccc.com>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 109f9b,ad83af236ce47a65 X-Google-Attributes: gid109f9b,public X-Google-Thread: 112d1e,ad83af236ce47a65 X-Google-Attributes: gid112d1e,public X-Google-Thread: 107cee,ad83af236ce47a65 X-Google-Attributes: gid107cee,public X-Google-Thread: 10d137,ad83af236ce47a65 X-Google-Attributes: gid10d137,public X-Google-Thread: 1118be,ad83af236ce47a65 X-Google-Attributes: gid1118be,public X-Google-Thread: 111d0a,ad83af236ce47a65 X-Google-Attributes: gid111d0a,public X-Google-Thread: 10026f,c4ce15d3e10cd212 X-Google-Attributes: gid10026f,public X-Google-Thread: 100bb0,c4ce15d3e10cd212 X-Google-Attributes: gid100bb0,public From: "William L. Bahn" <wbahn@uswest.net> Subject: Re: difference between instrumental amplifier and operational amplifier Date: 2000/03/14 Message-ID: <scste19qa5n33@corp.supernews.com> X-Deja-AN: 597419253 References: <89smse$fkl$1@news.cz.js.cn> <8alm5q$g85$1@copland.udel.edu> <8alnpa$pki$1@relay1.dsccc.com> Organization: Posted via Supernews, http://www.supernews.com X-MimeOLE: Produced By Microsoft MimeOLE V4.72.3110.3 Newsgroups: alt.engineering.electrical,cn.bbs.sci.electronics,misc.industry.electronics,misc.industry.utilities.electric,sci.electronics.basics,sci.electronics.components,sci.electronics.design,sci.electronics.misc X-Complaints-To: newsabuse@supernews.com