Article View: comp.dcom.lans.misc
Article #332Re: building wiring
From: Bert Robbins
Date: Tue, 26 Jan 1993 13:53
Date: Tue, 26 Jan 1993 13:53
35 lines
2247 bytes
2247 bytes
John K. Scoggin, Jr. (scoggin@delmarva.com) wrote: : In article 9AF@ra.nrl.navy.mil, atkinson@itd.nrl.navy.mil (Randall Atkinson) writes: : > [ redirected discussion from comp.protocols.tcp-ip :-] : > : > In article <1993Jan24.231044.16138@xenitec.on.ca> merce@xenitec.on.ca (Jim Mercer) writes: : > Actually most of the cost of cabling installation is in the labor, : > so it would be much wiser to put in Shielded Twisted Pair (STP), with : > 2 pair of wires per outlet. NB: Anything that will run over UTP will : > also run over STP, but the reverse is NOT true. STP is wisest and : > gives the most flexibility, with little real cost difference from UTP : > when you figure in installation costs. : > : This is NOT true. STP has a different impedance than UTP. We made the mistake : of wiring two large buildings with IBM Type 2 (STP) cable. We have had problems : running 10BaseT over long (75-100 meters) distances as a result. Believe me, : there is a BIG difference in cost between UTP and STP if you have to use plenum- : rated cable (Teflon)... We have recently acquired space that IBM had been leasing and had placed Type 2 wiring in. We were very glad to have the existing wiring to use. We are running 10BaseT on the piggy-backed 4 twisted-pairs of the Type 2 wiring, some lengths are 75-100 meters, and have experienced no problems at all. The existing TR connections have been used to connect up serial links to various equipment throught the building and works great. BTW, the twisted-pair runs through two punch blocks from the ethernet HUB, Penril S2000 Router, to the workstations and PCs. -- Bert Robbins Penril DataComm Networks bert@penril.com 1300 Quince Orchard Blvd 301/921-8600 x8856 Gaithersburg, MD 20872
Technical Details
Message-ID:
<C1GrxG.FJ@penril.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!penril!bertReferences:
<1k0nsgINNlvr@blackhole.delmarva.com>Show Full Headers
Complete Article Headers
Newsgroups: comp.dcom.lans.misc Path: arc1-ca.pugleaf.net!sparky!uunet!penril!bert From: bert@penril.com (Bert Robbins) Subject: Re: building wiring Message-ID: <C1GrxG.FJ@penril.com> Sender: news@penril.com (Penril News Service) Organization: Penril DataComm Networks X-Newsreader: TIN [version 1.1 PL8] References: <1k0nsgINNlvr@blackhole.delmarva.com> Date: Tue, 26 Jan 1993 13:53:40 GMT Lines: 35