In article <1992Aug31.122642.7992@access.digex.com>, zbang@access.digex.com (Carl P. Zwanzig) writes:
> BTW, What most people have in their houses is "split phase", not "two phase".
> The former is derived from a single transformer winding with 240v from
> end to end and a center tap, which is the grounded neutral. "Two phase" is
> a setup that requires 3 or 4 wires and generator windings that are electricly
> 90 degrees out of phase. It is only used in very old industrial plants
> anymore.
Another alternative is using 2 phases of a 3 phase suppply - not very common,
but it gives you 415 volts in Australia, or about 190 volts in USA. Then
again, using either 2 or 3 phases as 2 or 3 single phase supplies provides
crude balancing between phases.
Regards,
John Bennett E-mail: bennett@dstos3.dsto.gov.au
Head, Networks Group Phone : +61 8 259 5292
Corporate Information Systems FAX : +61 8 259 5537
DEFENCE SCIENCE AND TECHNOLOGY ORGANISATION Postal: Bld 73 Labs Area
AUSTRALIA PO Box 1500 Salisbury
"Lord Warden of the Sync Ports" South Australia 5108
(DSTO Network Manager) AUSTRALIA
Technical Details
Message-ID:
<1992Sep3.163324.164454@dstos3.dsto.gov.au>Path:
arc1-ca.pugleaf.net!sparky!uunet!munnari.oz.au!yoyo.aarnet.edu.au!dstos3.dsto.gov.au!bennettReferences:
<1992Aug24.212459.17668@mnemosyne.cs.du.edu> <1992Aug31.080450.1@cc.curtin.edu.au> <1992Aug30.215409.3729@spcvxb.spc.edu> <1992Aug31.122642.7992@access.digex.com>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!munnari.oz.au!yoyo.aarnet.edu.au!dstos3.dsto.gov.au!bennett From: bennett@dstos3.dsto.gov.au Newsgroups: comp.sys.dec Subject: Re: WANTED old PDP-11? Message-ID: <1992Sep3.163324.164454@dstos3.dsto.gov.au> Date: 3 Sep 92 22:33:23 GMT References: <1992Aug24.212459.17668@mnemosyne.cs.du.edu> <1992Aug31.080450.1@cc.curtin.edu.au> <1992Aug30.215409.3729@spcvxb.spc.edu> <1992Aug31.122642.7992@access.digex.com> Organization: Defence Science and Technology Organisation Lines: 22