dave@daveanderson.com (Dave Anderson) wrote:

>In <4jrnao$6pa@panix2.panix.com>, mreg@panix.com (Mitch Regenbogen) writes:
----- snip ------------

>You *must* have a terminator within about 4 inches of each end of the 
>cable, and *must not* have any other terminators.  Other than that, it
>doesn't matter which connecters are used and what's plugged into them.

>In your case, you must connect one of your devices to the connector at the 
>other end of the cable and must set that device to provide termination. 
>The other device can use any of the remaining 3 connectors, but must be set
>to not provide termination.

>        Dave

The termination must be at this place, not neccessarily a device ...
nothing is wrong if you have the devices all in the middle, and
terminate with a termination plug ....

Gerhard
Technical Details
Message-ID: <4k0f5h$15s@salomon.zfe.siemens.de>
Path: arc1-ca.pugleaf.net!news.mchp.siemens.de!news
References: <4jrnao$6pa@panix2.panix.com> <4jsp0e$6h9@news.tiac.net>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!news.mchp.siemens.de!news
From: gerhard.islinger@mch.sbs.de (Gerhard Islinger)
Newsgroups: comp.sys.ibm.pc.hardware.storage,comp.periphs.scsi
Subject: Re: Using multi-connector SCSI cable
Date: Thu, 04 Apr 1996 13:23:26 GMT
Organization: Siemens AG
Message-ID: <4k0f5h$15s@salomon.zfe.siemens.de>
References: <4jrnao$6pa@panix2.panix.com> <4jsp0e$6h9@news.tiac.net>
Reply-To: gerhard.islinger@mch.sbs.de
NNTP-Posting-Host: sysiphus.zfe.siemens.de
X-Newsreader: Forte Free Agent 1.0.82