Digital, 3COM et al recommend RG58C/U for "thin wire" Ethernets. RG58C/U
various only slightly in construction from (the 70% more expensive) more
common RG58A/U. The major difference is that C/U has a "non-contaminating"
vinyl jacket...which apparently means that if it catches fire the fumes are
less harmful to humans.
Trying to decide which cable to buy in bulk, I came across another RG58A/U
type cable (trade/Belden number 8219) with a cellular (foamed) polyethylene
internal insulation and a higher velocity propagation (.78c instead of .66c
for regular RG58A/U and C/U). Curiously enough it seems to have exactly
the same electrical characteristics as regular "thick" Ethernet cable (same
capacitance and apparently same LC).
Assuming I don't need non-contaminating jacketed C/U, this looks like the
cable of choice for thin Ethernet.
Question: has anybody tried it? Are thinwire transceivers (e.g. 3COM
units) really tuned specifically for C/U-A/U cables, or is it reasonable to
suspect that 8219 is actually a better cable for thinwire applications?
--
Bob Cunningham {humu|ihnp4}!{islenet|uhmanoa}!bob
cunninghamr%haw.sdscnet@LLL-MFE.ARPA
Hawaii Institute of Geophysics, University of Hawaii
Technical Details
Message-ID:
<2758@islenet.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!seismo!gatech!akgua!lcuxlm!whuxl!houxm!ihnp4!islenet!bobShow Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!mnetor!seismo!gatech!akgua!lcuxlm!whuxl!houxm!ihnp4!islenet!bob From: bob@islenet.UUCP (Bob Cunningham) Newsgroups: net.lan,net.dcom Subject: 8219 better for thin wire than RG58C/U? Message-ID: <2758@islenet.UUCP> Date: Wed, 20-Aug-86 13:58:25 EDT Article-I.D.: islenet.2758 Posted: Wed Aug 20 13:58:25 1986 Date-Received: Fri, 22-Aug-86 06:44:54 EDT Distribution: na Organization: Hawaii Institute of Geophysics Lines: 23